Specifications

Danish Interpretation Systems Technical Specifications
Printed in Denmark
41
The votes of a delegate is only valid, if the address is not 0 and the Vote is not 0:
Example:
Imagine, that the CU has received a Yes-vote from address 3 and a No-vote from address 20.
The CU ‘packs’ the votes of both units into the same message.
<START> 'c' <ID> <15> <173> <69> <8> <0> <19> <1> <52> <0> <0> <0> <18> <CRC> <STOP>
For Address 1 we have:
Address 1 = 16* <Vote MSB addr1> + <Vote LSB addr1 [Bit3-Bit0]>
= 16 * 0 + 3 = 3
Vote 1 = <Vote LSB addr1 [Bit7-Bit4]>
= 1 (Yes-vote from address 3)
For Address 2 we have:
Address 2 = 16* <Vote MSB addr2> + <Vote LSB addr2 [Bit3-Bit0]>
= 16 * 0 + 3 = 3
Vote 2 = <Vote LSB addr2 [Bit7-Bit4]>
= 3 (No-vote from address 20)
For Address 3 and Address 4 there is no information (all is 0).
4.6 Summary of status control messages (CU
External control unit)
Below, all the status control messages that can be sent from the CU to an external control unit are
listed.
MAIN_GRP (=1):
Command Item value
Comment
MAIN_LOST_UNIT
4 A unit has become passive (lost) in
the DCS6000 system
MAIN_FOUND_UNIT
26 A unit has become active (found) in
the DCS6000 system
EXTERNAL_CONTROL_GRP (=27):
Command Item value
Comment
EXTERNAL_UNIT_ADDRESS
2 Registration reply to an external
control unit.