Specifications

Danish Interpretation Systems Technical Specifications
Printed in Denmark
15
MICROPHONE_CONTROL_CLEAR_REQUEST_LIST
Command item value: 8
Message format:
<START> ‘j’ <ID> <0> <MSB addr> <LSB Addr> <18> <8> <0> <0> <CRC> <STOP>
Clears the request list.
MICROPHONE_CONTROL_SET_MAXSPEAKERS
Command item value: 12
Message format:
<START> ‘j’ <ID> <0> <MSB addr> <LSB Addr> <18> <12> <Max Speakers> <0> <CRC> <STOP>
Set the maximum number of simultaneously active delegate microphones to Max Speakers. Chairman
units are not included in this count. Regardless of the setting of this parameter the maximum number
of active microphones (delegates + chairmen) is 8. The range of Max Speakers is 0-8.
MICROPHONE_CONTROL_SET_MAXREQUESTS
Command item value: 13
Message format:
<START> ‘j’ <ID> <0> <MSB addr> <LSB Addr> <18> <13> <Max Requests> <0> <CRC> <STOP>
Sets the maximum number of delegates in the request queue to Max Requests the range is 0-255.
MICROPHONE_CONTROL_MICROPHONE_ON
Command item value: 14
Message format:
<START> ‘j’ <ID> <0> <MSB addr> <LSB Addr> <18> <14> <Microphone Addr MSB> <Microphone Addr LSB> <CRC>
<STOP>
Activates the microphone with the address 256*Microphone Address MSB + Microphone Address
LSB. See section 5.2 for a description of how to find the microphone addresses.
MICROPHONE_CONTROL_MICROPHONE_OFF
Command item value: 15
Message format:
<START> ‘j’ <ID> <0> <MSB addr> <LSB Addr> <18> <15> <Microphone Addr MSB> <Microphone Addr LSB> <CRC>
<STOP>
Deactivates the microphone with the address 256*Microphone Address MSB + Microphone Address
LSB.