SDS

RR-808 ROOF REPAIR AHE80812BK0
Product name
4
Product code
Date of issue
Version
00407690
17 August 2015
Section 4. First aid measures
Protection of first-aiders
:
No action shall be taken involving any personal risk or without suitable training. It may
be dangerous to the person providing aid to give mouth-to-mouth resuscitation.
Notes to physician
:
In case of inhalation of decomposition products in a fire, symptoms may be delayed.
The exposed person may need to be kept under medical surveillance for 48 hours.
Specific treatments
:
No specific treatment.
Skin contact
Ingestion
Adverse symptoms may include the following:
stomach pains
Adverse symptoms may include the following:
irritation
redness
dryness
cracking
:
:
See toxicological information (Section 11)
Indication of immediate medical attention and special treatment needed, if necessary
Section 5. Fire-fighting measures
Promptly isolate the scene by removing all persons from the vicinity of the incident if
there is a fire. No action shall be taken involving any personal risk or without suitable
training. Move containers from fire area if this can be done without risk. Use water
spray to keep fire-exposed containers cool.
Hazardous thermal
decomposition products
Specific hazards arising
from the chemical
Decomposition products may include the following materials:
carbon dioxide
carbon monoxide
nitrogen oxides
metal oxide/oxides
Flammable liquid and vapor. In a fire or if heated, a pressure increase will occur and
the container may burst, with the risk of a subsequent explosion. Vapors may
accumulate in low or confined areas or travel a considerable distance to a source of
ignition and flash back. Runoff to sewer may create fire or explosion hazard. This
material is harmful to aquatic life with long lasting effects. Fire water contaminated with
this material must be contained and prevented from being discharged to any waterway,
sewer or drain.
Fire-fighters should wear appropriate protective equipment and self-contained breathing
apparatus (SCBA) with a full face-piece operated in positive pressure mode.
Special protective
equipment for fire-fighters
Use dry chemical,
CO₂,
water spray (fog) or foam.
Extinguishing media
:
:
:
Do not use water jet.
Suitable extinguishing
media
:
Unsuitable extinguishing
media
:
Special protective actions
for fire-fighters
:
United States
Page: 4/14