REGULATORY COMPLIANCE TAG
Explosive Atmospheres symbol
IECEX DNV 11.0012X
This equipment has been found to comply with the Certication Scheme for Explosive Atmospheres of INTERNATIONAL
ELECTROTECHNICAL COMMISSION (IECEx). Evaluation was made in 2013 by Det Norske Veritas (DNV) to IECEx scheme
with a certicate number IECEx DNV 11.0012X, where X represents the following Special Conditions for Safe Use: 1) Only Ex
d certied cable glands are to be used; and 2) For ambient temperatures above 70 °C, use eld wiring suitable for 20°C above
maximum ambient temperature.
II
Suitable for use in surface (not mine) installations.
2 G
High level of protection is provided against ammable gases, vapors, or liquids, which may exist during normal operation.
Ex d
Explosion protection is provided by a ameproof enclosure.
IIB
Gas group, which includes ethylene, propane, and methane.
T6:
Temperature class for surface temperature limitations. T6 is ≤ 85ºC
Gb
Equipment group per IEC 60079-0:2007.
amb
Safe limits of ambient temperature.
IP66
Ingress protection: dust tight and protected against powerful water jetting.
Consult factory for current compliance status.