Manual

SP4000 Flow Computer
18
3.6 Liquid Combustion Heat
Measurements:
Actual volume flow is measured by the flowmeter. Temperature is measured by the
temperature transmitter. A pressure transmitter can be used to monitor pressure. Pressure
measurement does not affect the calculation.
Calculations:
The density, mass flow and combustion heat are calculated using the fluid
characteristics stored in the flow computer. (see "FLUID DATA" submenu)
Output Results:
Display Results
Combustion Heat, Mass or Volume Flow Rate, Resettable Total, Non-Resettable
Total, Temperature, Pressure, Density (optional: peak demand, demand last
hour, time/date stamp)
Analog Output
Combustion Heat, Mass or Volume Flow Rate, Temperature, Pressure, Density,
Peak Demand, Demand Last Hour
Pulse Output
Combustion Heat, Mass or Volume Total
Relay Outputs
Combustion Heat, Mass or Volume Flow Rate, Total, Temperature, Pressure
Alarms, Peak Demand, Demand Last Hour
Applications:
Calculate the energy released by combustion of liquid fuels
LIQUID COMBUSTION
HEAT
Liquid Combustion
Heat Illustration
Volume Flow
As calculated in section 3.4
Heat Flow
Heat Flow = C volume flow (1-α (T
1
-T
ref
))
2
ref. density
α = Thermal expansion coefficient 10
-6
C = Specific combustion heat
Calculations
Flowmeter Temperature
Transmitter
PRINT
5
0
TIME
CLEAR
MENU
ENTER
HELP
TEMP
4
PRE 1
3
RATE
2
TOTAL
1
GRAND
6
SCROLL
7
PRE 2
8
DENS
9
Optional
Pressure
Transmitter
T
1