User Manual

73
SP3850 Flow Computer
Appendix B
SETUP MENUS
AUX1 INPUT
TYPE
CURRENT
RANGE
OFFSET
TEMPERATURE
AUX LOW
SCALE
DENS EXTRACT
METHOD
SETUP AUX1 INPUT
AUX1 SIGNAL
TYPE
HIGH TEMP
TOT LIMIT
AUX FULL
SCALE
SETUP
INDICATORS
TOTAL
DESCRIPTOR
VOLUME UNITS
TOTAL DEC
PLACES
DENSITY
DESCRIPTOR
MASS UNITS
DENSITY DEC
PLACES
DENSITY
DEFAULT
RATE TIME
BASE
RATE
DESCRIPTOR
RATE DEC
PLACES
RATE AVERAGE
FILTER
QUICK
UPDATE %
TEMP
DESCRIPTOR
TEMPERATURE
SCALE
EXCITATION
VOLTAGE
PULSE INPUT
TYPE
PULSE
TRIGGER TYPE
LOW PASS
FILTER
INPUT
TERMINATION
MAX WINDOW K-FACTOR
TYPE
AVERAGE
KA-FACTOR
INSTRUMENT
TYPE
BATCH COUNT
MODE
MAX. BATCH
PRESET
BATCH
OVERRUN
COMP.
AUTO BATCH
RESTART
MAX. DRAIN
TIME
CHOOSE FLUID
MEDIUM
SELECT FLOW
EQUATION
FLUID NUMBER FLUID NAME REF. DENSITY REF.
TEMPERATURE
EXPANSION
FACTOR
SERIAL
HARDWARE
DEVICE ID BAUD RATE
PARITY HANDSHAKE DEVICE LINE
FEED
TAG NUMBER OPERATOR
PASSWORD
SUPERVISOR
PASSWORD
SOFTWARE
VERSION
INSTRUMENT
TYPE
ADMINISTRATIVE SETUP
SERIAL USAGE
SETUP PULSE OUTPUT
SET FLUID PROPERTIES
SETUP FLOW INPUT
SETUP INDICATORS
SELECT FLOW EQUATION
SLOW START
QUANTITY
PRODUCT
ORDER CODE
UNIT SERIAL
NUMBER
SENSOR SERIAL
NUMBER
DISPLAY NEW
ERROR ONLY
These functions will only appear with appropriate
settings in other functions.
SETUP
RELAYS
1, 2, 3, 4
RELAY
DURATION
ASSIGN AUX
CHANNEL
RELAY
SETPOINT
RELAY USAGE
RELAY
DELAY
SETUP RELAYS
RELAY
HYSTERESIS
RELAY MODE
SETUP REAL
TIME CLOCK
ENTER DATE
SELECT
CLOCK AM/PM
TIME OF DAY
SETUP REAL TIME CLOCK
MODEM
OPTIONS
MODEM INIT
MASTER
NO TOT FOR
BATCH DELAY
CALL ON
ERROR/ALARM
NUMBER OF
REDIALS
HANGUP IF
2MIN. INACTIVE
MODEM AUTO
ANSWER
CALL OUT NO
CALL OUT DAY
OF WEEK
START HERE
TEMPERATURE
DEC PLACES
AVERAGE
KB-FACTOR
TEMPERATURE
DEFAULT
PRESSURE
UNITS
PRESSURE
DESCRIPTOR
PRESSURE
UNITS
PRESSURE
DEC PLACES
PRESSURE
DEFAULT
BAROMETRIC
PRESSURE
CHANGE
TABLE A
CHANGE
TABLE B
LOW FLOW
RATE ALARM
HIGH FLOW
RATE ALARM
H20 DENSITY
AT 4DEGC
METER
EXPANSION
CALIBRATION
TEMPERATURE
AUX2 INPUT
TYPE
VOLTAGE
RANGE
AUX LOW
SCALE
AUX FULL
SCALE
AUX LOW
ALARM
SETUP AUX2 INPUT
AUX2 SIGNAL
TYPE
CURRENT
RANGE
AUX HIGH
ALARM
DENS EXTRACT
METHOD
VISCOSITY
COEF. A
VISCOSITY
COEF. B
PULSE OUPUT
USAGE
PULSE WIDTH PULSE VALUE
ANALOG
OUPUT USAGE
ANALOG OUT
LOW SCALE
ANALOG OUT
FULL SCALE
ANALOG OUT
DAMPING
SETUP ANALOG OUTPUT
ANALOG OUT
RANGE
CONTROL
INPUT 1 USAGE
CONTROL
INPUT 2 USAGE
CONTROL
INPUT 3 USAGE
SETUP CONTROL INPUTS
SETUP
CONTROL
INPUTS 1, 2, 3
CLOCK TYPE
CALL OUT
TIME
SETUP
DATALOG/
PRINT
OUTPUT
FORMAT
PAGE LENGTH TOP MARGIN
CLEAR TOTAL
IF PRINT
PRINT LIST
ITEMS
SETUP
DATALOG/PRINT
DATALOG
ONLY
PRINT TIME
PRINT
INTERVAL
ENABLE PRINT
KEY
TIME DELAY
LOW TEMP
TOT LIMIT
REFERENCE
PRESSURE
Z-FACTOR
REFERENCE
Z-FACTOR
FLOWING
ANALOG OUT
FLOW TYPE
SELECT
NETWORK
PROTOCOL
NETWORK
DEVICE ID
BAUD RATE
PARITY
SETUP NETWORK CARD
PRINT END OF
BATCH
FLOW SIGNAL
TIMEOUT
INH START/
STOP KEYS