User Manual

7
SP3850 Flow Computer
3. Applications
3.1 Liquid Volume
Measurements:
A flowmeter measures the actual volume in a liquid line. A temperature
sensor can also be installed to correct for liquid thermal expansion (see
3.2 Corrected Volume).
Calculations:
Volume flow is calculated using the flowmeter frequency output and the
user entered K-Factor.
Output Results:
Display Results
Flow Rate, Resettable Total, Non-Resettable Total
Analog Output
Rate or Total
Pulse Output
Total
Relay Outputs
Rate or Total Alarms
Applications:
The Flow Computer can monitor actual volume flow and total of any
liquid. Flow alarms are provided via relays and datalogging is available
via analog (4-20mA) and serial outputs.
Liquid Volume
Pulse Input; Average K-Factor
input frequency • time scale factor
Volume Flow =
K-Factor
Liquid Volume
Illustration
Calculations