Manual

57
COMMAND CATEGORIES:
SET Sets variables & parameters
Command Keywords:
EXAMINE Examines variables & parameters
RUN Start the instrument
STOP Stop the instrument
CLEAR Alarm or Totalizer
LOCK Locks instrument
UNLOCK Unlocks instrument
SYSDUMP Show everything
“X” Command Shows specific piece of information
SET COMMANDS:
SET COMMANDS allow functions to be set remotely.
SET COMPUTATIONS - Sets the computations that will be used for Volume, Mass, or Heat Flow
SET UNITS - Sets engineering units of the instrument to English or Metric.
SET HARDWARE - Sets specific hardware parameters of the instrument.
SET TIME - Sets the internal real time clock.
SET DATE - Sets the internal date of the instrument.
SET LIST - Sets up the list of calculated values that will be printed through the serial port while
running.
SET EXCEPTION - Turns exception reporting ON or OFF.
SET COMPUTATIONS
Reference: See Section 3.2
Format: SET COMPUTATIONS [text] (CR)
Function: Computation units set depending on text string:
REQUIRED TEXT
VOLUME (Ideal Gas-Volume)
MASS (Ideal Gas-Mass)
STEAM (Steam Tables- Mass)
LIQMASS (Liquids- Mass)
LIQVOL (Liquids- Volume)
HEATGAS (Heat- Gas)
HEATSTEAM (Heat- Steam)
HEATLIQUID (Heat- Liquid)
DEL HEAT (Del Heat- Liquids)
Example: SET COMPUTATIONS HEATSTEAM (CR)
SET UNITS
Reference: See Section 3.4
Format: SET HARDWARE [text] (CR)
Function: The SET HARDWARE command parallels the Hardware Setup menu. The user may
configure the input hardware using this command.