STEP
4
SETTING
THE
RATEMETER
CLR
CLR
5
ENT
CLR
6
PRESS DISPLAY
MENU FLASHES TO DEV TYP
RT CNT (RATE OR COUNT)
(SET UP RATEMETER) K FACTOR FLASHES; THEN SHOWS
CURRENT K-FACTOR
0 FLASHES
1 7 . 8 FLASHES
(PRESS D FOR DECIMAL POINT)
K FACTOR IS DIVIDER. IT CONVERTS INPUT TO ENGINEERING UNITS.
(K FACTOR ENTERED) WINDOW ##
WINDOW 00
(AS AN EXAMPLE) WINDOW 05
(EXTENDS THE SAMPLING WINDOW TO 5 SECONDS)
(WINDOW ENTERED) SIG FIG ##
SIG FIG 00
(AS AN EXAMPLE) SIG FIG 06
(SIG FIG INDICATES HOW MANY MEANINGFUL DIGITS ARE SHOWN
TRAILING ZEROS ARE INSERTED IF NECESSARY)
(SIG FIG ENTERED) WEIGHT #.#
WEIGHT 0.0
(AS AN EXAMPLE) WEIGHT 9.9
WEIGHT IS AN AVERAGING FACTOR. HIGHER SETTINGS PROVIDE MORE AVERAGING, FOR A
MORE STABLE DISPLAY. DERIVED FROM:
(WEIGHT ENTERED) LAST COUNT READING
MENU FLASHES TO DEV TYP
LOCKOUT
(LOCKOUT SELECTED) CODE FLASHES; THEN SHOWS OLD CODE #.
0 FLASHES
(AS AN EXAMPLE) 1 1 1 1 FLASHES
(CODE ENTERED) PR LCK PR UNLK
(LOCKOUT OF (LOCKOUT OF ALL FRONT
FRONT PANEL) BUTTONS EXCEPT
PRESETS A, B AND CLR)
(LOCKOUT SELECTION ENTERED) LAST COUNT READING
LOCK ON FLASHES
(APPROPRIATE PANEL CHANGES LOCKED OUT)
LOCK OFF FLASHES
(PANEL CHANGES ALLOWED)
ENT
4
D
ENT
CLR
1
1 1 1
ENT
ENT
1
1 1 1
1
1 1 1
(OLD DATA x "WEIGHT" + NEW DATA)
("WEIGHT" + 1)
ENT
99
STEP
5
SETTING
LOCKOUT
CODE
CLR