Owner's manual

INITIAL SET-UP MODE
Hold down “RESET” key and turn power “ON”
The prover “SET-UP menu will be displayed.
Press “PRINT” key
Set-up ticket will be printed.
Example:
<<<<<<<<>>>>>>>
>
Fl o- cal set up
03: 35P 14- Jul -
97
Pr oduct
0 - L OX
1 - LI N
2 - LAR
3 - L CO2
4 - LN20
5 - CC0 2
6 - MAPP
7 - LPG
= Fact or
R = . 4063
T = . 779419
R = . 4063
T = . 63051
R = . 4063
T = . 761813
R = . 4063
T = . 057356
R = 0
T = 0
R = . 4063
T = . 057356
R = 0
T = 0
R = 0
T = 0
Note: Each SP1200 is factory calibrated for products and engineering units of total as specified by user.
Calibration Factors
Rate is always Gallons per minute (Gm)
Rfactor = 60/K
Totalization may be any engineering units.
Tfactor - Engineering Units/K
The prover “SET-UP menu will be displayed.
NOTE: If prover was factory calibrated DO NOT select Set-up option “3-Factor”. If printed set-up data is
incorrect, incomplete or missing call factory.
1 = Clock
2 = RTD
4 = More
1 = Clock
2 = RTD
4 = More