Setup & Operation User guide

46
Appendix B - Operation Using VT 100 Compatible Terminal
If the LCR is operated using a VT 100 compatible terminal (instead of the LC Lap Pad), refer to the following chart for
the terminal keystrokes that correspond to the Lap Pad keystrokes. VT 100 communication parameters that must be
observed include:
Baud Rate (9600)
Data Bits (8)
Parity (None)
Stop Bits (1)
Flow Control (None).
Operation Lap Pad Keystroke PC Terminal Emulation
Return to Top Level Menu M1 <control L>
Move to Next Menu Item
L
<control D>
Move to Previous Menu Item
K
<control U>
Select Item ENTER ENTER
Submit Data and Return ENTER (after data entry) ENTER (after data entry)
Move to Next Field
L
<control D>
Move to Previous Field
K
<control U>
Clear Field/Start Data Entry Clear Backspace
Start Start <control B>
Stop Stop <control S>
Print Print <control P>
Move to Next Screen M# <control N>