Setup & Operation User guide
45
Appendix A - Compensation Types & Parameters
The table below shows the supported methods of calculating the Volume Correction Factor (VCF). The method is
independently select able for each product in Product Calibration. The table below shows the valid temperature
ranges for each table. The hold temperature, T
hold
, is the temperature that VCF is held at for temperatures < T
hold
and
> T
min
. This is done to allow compensation in very cold environments where further extrapolation of equations is not
allowed.
General Linear Linear 0 to 0.003 ºC 15 -90 N/A +100
General Linear Linear 0 to 0.005 ºF 60 -130 N/A +212
LPG
USA
LPG
Europe &
Canada
Refined
Petroleum
Products
Europe &
Canada
Refined
Petroleum
Products
USA
General API Table 54C Coefficient
0.000486 to
0.001674
ºC 15 -50 -40 +95
Lube Oil
Europe &
Canada
Ammonia
Canada
Density
kg/m3
Density
kg/L
T
base
T
min
T
hold
Product VCF Type
Parameter
Coefficient
Range
T
max
API Table 24
Specific
Gravity
0.5 to 0.550 ºF 60 -50 -50 +140
Scale
ºC or ºF
API Table 54 0.5 to 0.600 ºC 15 -46 -46 +60
API Table 54B 653.0 to 1075.0 ºC 15 -50 -40 +95
-50 -40 +200API Table 6B API Gravity 0 to 85 ºF
NH
3
N/A N/A
60
Density
kg/m3
API Table 54
D 800 to 11
64 ºC 15
ºC +40
-5
0 -40 +95
15 -30 -30