Wire Connection Tables
RTD TEMP. PROBE CONNECTION (J14)
VALVE SOLENOID CONNECTION (J13)
NOTE: Pull-down resistors of 300 Ω needs to be
connected between CHAN B and GND, and CHAN A and
GND.
AUXILIARY OUTPUTS (J12)
VEEDER ROOT SOLID STATE QUAD
PULSER (J8)
SINGLE CHANNEL PULSER (J8)
LIQUID CONTROLS POD (J8)
NOTE: To operate a single channel pulser, a jumper is
required between pins 2 and 3 on J4.
Connector/
Pin
Signal Wire Color Route To:
J12-45 +Vo N/A
44
Out 1
(Aux. 1)
N/A
Pump or
Aux. Control
43
Out 2
(Aux. 2)
N/A Flow Direction
42 Out 3 N/A
Pulse Input for
Aux. System
41 GND N/A
40 Out 4 N/A Display Input
39 Out 5 N/A Display Input
Connector/
Pin
Signal Wire Color Route To:
J8-38 - - -
37 GND Black Pulser Signal GND
36 - - -
35 - - -
34 In 3 Green Channel B Output
33 In 4 White Channel A Output
32 - - -
31 +Vo Red +V Input
Connector/
Pin
Signal Wire Color Route To:
J8-38 - - -
37 GND N/A Pulser Signal GND
36 - - -
35 - - -
34 -
33 In 4 N/A Pulse Output
32 - - -
31 +Vo Red +V Input
Connector/
Pin
Signal Wire Color Route To:
J8-38 - - -
37 GND White Pulser Signal GND
36 - - -
35 - - -
34 In 3 Orange Channel B Output
33 In 4 Black Channel A Output
32 - - -
31 +Vo Red +V Input
Connector/
Pin
Signal Wire Color Route To:
J13-19 Earth Green
Solenoid 2
Case Ground
18 Out 6 Black or Red Solenoid 2
17 +Vo Black or Red Solenoid 2
16 Earth Green
Solenoid 1
Case Ground
15 Out 7 Black or Red Solenoid 1
14 +Vo Black or Red Solenoid 1
Connector/
Pin
Signal Wire Color Route To:
J14-23 RTD-D White RTD
22 RTD-S White RTD
21 RTD+D Red RTD
20 RTD+S Red RTD