User Manual
7
RATE
TOTAL
M
RUN MODE
CLEAR TOTAL
FACTOR
DECIMAL
FACTOR
ENTER CODE
If panel
lock ON
If panel
lock OFF
If code
correct
If code
incorrect
FACTOR
TYPE
selected
E
M
E
E
M
E
M
E
M
selected
#####
#####
If Fr# = 0
If FAC# = 0
# = 10
E
M
E
M
FACTOR
MULTIPLIER
E
M
E
M
SET 10PT
selected
selected
Press the M key to enter the programming menu.
The prompt will only appear if is selected. This allows
users to bypass the 10 point set up and keep the existing values.
Press the key to choose YES or NO.
Press the E key to enter the displayedselection.
Press the M key to skip (same as selecting NO).
If the panel lock is on, you must enter the 4 digit lock code to gain access
to the menu.
Press the
key to increment each individual digit of the code.
Press the key to advance to the next digit.
Press the E key to enter the displayed code.
If the code is correct, display advances to " ", if not, display returns
to run mode
Press the E key to clear the totalizer and return to the programming menu.
Press the M key to skip and go to next menu item.
Press the key to choose the factor multiplier ( , , , ).
Press the E key to enter the displayed factor multiplier.
Press the M key to skip and keep the existing factor multiplier.
Press the
key to step the factor decimal to the desired location.
Press the E key to enter the displayed decimal location.
Press the M key to skip and keep the existing location
Press the
key to choose factor type ( or ).
Press the E key to enter the displayed factor type.
Press the M key to skip and keep the existing factor type.
Press the key to increment each individual digit of the factor for point #.
Press the
key to advance to the next digit.
Press the E key to enter the displayed factor.
Press the M key to skip and keep the existing factor.
If 0 is entered, the display will advance to the next prompt (tdec).
Press the
key to increment each individual digit of the frequency for
point #.
Press the key to advance to the next digit.
Press the E key to enter the displayed frequency.
Press the M key to skip and keep the existing frequency.
If 0 is entered, the display will advance to the next prompt (tdec).
The prompt will only appear if is selected or if the unit was
ordered without the 10 point linearization option.
Press the
key to increment each individual digit of the factor.
Press the key to advance to the next digit.
Press the E key to enter the displayed factor.
Press the M key to skip and keep the existing factor.