User Manual

HML4-F1
5
TECHNICAL CHARACTERISTICS
ENVIRONMENTAL USE CONDITIONS
AMBIENT TEMPERATURE
Da
ta plate
On the data plate there is some technical information:
Conv. Mod.: converter Model
Conv. s/n: converter Serial Number
P.S.: power supply
Power: maximum power consumption
Sensor Mod.: serial number of sensor coupled
Sens s/n: serial Number of the sensor
DN: sensor nominal diameter
PN: sensor nominal pressure
IP: Protection grade
Fittings: process connections
Lining: sensor lining
Max Temp: maximum sensor temperature
Electrodes: sensor electrodes
KA: sensor KA
ITEM: free for user
Min. *
Max.
1
°C
-20
60
°F
-4
140
ELECTRICAL CHARACTERISTICS
Converter classification: class I, IP 67,
installation category (overvoltage) II, rated
pollution degree 2.
Power supply
versions
Power supply
voltage
Max
power
LLV
18-30V
10W
q Voltage variations must not exceed ±10% of the nominal one.
q Input/output are insulated up to 500V
q The output 4-20 mA (optional) is electrically connected
q
The converter can be installed inside or outside buildings
q Altitude: from 200 to 2000m (from -656 to 6560 feet)
q Humidity range: 0-100% (IP 67)
Consider the ambient temperatures more restrictive between converter and sensor.
*
= For discontinuous use, the installation of a heating resistance is necessary.
1
= For liquid temperature > 60°C , ambient temperature max 40°C
130°C Cip (cleaning in place) is allowed up to 30’ (unlimited time if converter switch off)