SYSTEM SETUP 1
Meter ID: (TB) C
The identication number of the owmeter the LCR 600 is mounted
on. If the LCR 600 is installed in a multiple-meter system, it is
important this number be unique. The number is printed on the
calibration/diagnostic ticket. LC recommends entering the owmeter’s
serial number to ensure identication.
Unit of Measure: (LB) C
The unit of ow measurement.
Gallons • Litres • Cubic M • Lbs (pounds) • Kgs •
Barrels • Other
Decimal Digit: (LB) C
FlightConnect
The decimal place of volume measurements shown on the display and printed tickets.
Whole
is the preferred
FlightConnect setting.
Hundredths • Tenths • Whole
Residual Processing: (LB) C
The treatment of excess decimal places when displaying and printing volume measurements.
Round
is the preferred
FlightConnect setting.
Round
Truncate
Flow Rate Base: (LB) C
The time unit of the measured ow rate.
Per Minute
is the preferred FlightConnect setting.
Per Second • Per Minute • Per Hour
Flow Direction: (LB) C
The direction of ow through the owmeter. If the LCR 600 is counting in reverse (decreasing numbers), select the
opposite Flow Direction.
<− • −>
Printer: (LB) C
The type of printer connected to the LCR 600.
EPSON NewFontB
EPSON NewFontA
EPSON OldFontA
EPSON OldFontB
OKIDATA ML184T
BLASTER
Ticket Required: (LB) C
FlightConnect
Determines if the printer is required to be online and ready to print in order to start a fueling. Most Weights &
Measures governed truck applications require a ticket.
Yes
is the preferred FlightConnect setting.
Yes
Skip
No
dP Shutdown Value: (TB) C
FlightConnect
The differential pressure amount that will shut down an active fueling. This feature pertains to owmeter systems
with a differential pressure transducer and requires a shutdown device. If the value is set to 0, the feature is disabled.
0-59.9 range.
Next/Previous Screen
SYSTEM SETUP 1
Meter ID:
Unit of Measure:
Decimal Digits:
Residual:
Flow Rate Base:
Flow Direction:
Printer:
Ticket Required?
dP Shutdown Value:
LCR Node Address:
Delivery Screen:
A101
GALLONS
TENTHS
ROUND
PER MINUTE
->
EPSON OldFontA
YES
25.0
250
Aviation
L - Locked
U - Unlocked
C - Weights & Measures Calibration
P - Stop/Pause
F - Factory
Security Clearance