User Manual
16
LOCKED
An owner/ofce security setting that limits the access
of drivers to a small number of fueling, system, and
FlightConnect elds.
To lock the LCR 600
1. Select the Security screen from the Conguration Menu.
2. Move the pointer to User Key: eld and press the
EntEr button.
3. Enter an alphanumeric password in the text box and
press the EntEr button
4. Move the pointer to the Security: eld and press the
EntEr button.
5. Move the pointer to Locked in the list box and press
the EntEr button.
UNLOCKED
An owner/ofce security setting that allows drivers
access to a large number of fueling, system, and POS
elds.
To unlock the LCR 600
1. Select the Security screen from the Conguration Menu.
2. Move the pointer to User Key: eld and press the
EntEr button.
3. Enter the same alphanumeric password that was
entered when the LCR 600 was locked. The value of the
Security: eld will change to UNLOCKED.
Throughout this manual, each LCR 600 eld denition species the security levels
that allow access to the eld. The abbreviation for each security level is as follows:
L - Locked
U - Unlocked
C - Weights & Measures Calibration
P - Stop/Pause
F - Factory
WEIGHTS & MEASURES CALIBRATION
The Weights & Measures Calibration security setting
allows access to all elds and functions necessary
for Weights & Measures approval and the complete
conguration of the LCR 600 for service.
To enter the Weights & Measures Calibration mode
1. Remove the faceplate around the red selector switch.
If the LCR 600 was Weights & Measures approved
beforehand, you will need to remove the lead seal and
wire threaded through the switchplate screws.
2. Turn the selector switch to the six o’clock position.
STOP/PAUSE
FlightConnect fueling elds can be edited during
fuelings. Turn the selector switch to the STOP (pause)
position. The fueling will pause and the fueling screen
will appear on the LCR 600. Fueling elds can be edited
in the fueling screen. After editing a eld, the fueling can
be continued by turning the selector switch back to RUN.
FACTORY
A security setting restricted to LC factory personnel.
Levels of Security
Many LCR 600 elds are accessible only while certain security levels are accessed. The security levels provide the
safeguards essential for Weights & Measures approval, and they give owners and operators a means of restricting
drivers and fuelers access to certain functions. There are ve levels of security on the LCR 600: Locked, Unlocked,
Weights & Measures Calibration, Stop/Pause, and Factory.
INTRODUCTION - SECURITY
Six O’clock Calibration Position
LCR 600 units are shipped from the factory locked.
To unlock a factory shipped LCR 600:
User Key:
EntEr
EntEr
Factory Locked LCR 600s