Owner's manual
23
FleetConnect Read
(FCRead) Icon
FCRead (FleetConnect Read) Status Window
OPERATION
FCRead’s output (.csv, .asr, or .xml) is determined by
the TransFormat: option in the SysDefs tab (pg. 27) or
the Edit Record Validation setting in the Target: eld of
the FCRead Properties window (pg. 14).
Setting FCRead’s File Format Output
FCRead
FCRead converts transaction les sent from DMS
i1000s into les for use in FCEdit and your back ofce
accounting software application.
During fueling shifts in the eld, the DMS i1000(s)
compiles data recorded during deliveries into a
transaction le, Comp502.trn. The Comp502.trn le(s)
are then transferred, either wirlelessly from the DMS
i1000 or via a USB memory stick, into the C:\DMS folder
on your ofce computer.
When the FCRead program opens (or the Convert
button in the FCRead window is clicked on) on your
computer, FCRead will automatically convert the
Comp502.trn les into a text le (.csv, .asr, or .xml).
And, if the Edit Record Validation feature is activated and
a DMS i1000 added new database information during a
shift, FCRead will also create an edit transactions le,
Edit502.trn. This le will enact the Edit Record Validation
feature in FCEdit.
How you use FCRead will depend on the method of data
transmission your FleetConnect System uses.
FCREAD & DB MANAGER
If DB Manager is installed and wireless communication
is active, FCRead will automatically run every time a le
is received from a DMS i1000. Refer to the DB Manager
Installation & Setup Manual, EM200-21, for additional
information on DB Manager.
FCREAD & USB MEMORY DEVICE
If you are using USB memory devices to transfer data
between the DMS i1000s and the ofce PC, FCRead
must be activated manually.
To use FCRead with the
USB memory device:
1. Open the FleetConnect USB memory device on your
PC, drag and drop (or copy and paste) the transaction
le, Comp502.trn, from the USB device into the C:\DMS
folder.
2a. Double-click the FCRead icon to open the FCRead
window. Opening the window will convert the Comp502.
trn le in the C:\DMS folder into a CompTran.csv (or .asr
or .xml).
2b. If the FCRead window is open, click Convert to convert
the Comp502.trn into a CompTran.csv (or .asr or .xml).
FCREAD AUTOMATIC STARTUP
You also have the option of setting up FCRead to
automatically open every time your computer boots up.
To run FCRead each time your computer boots up:
1. Click Windows
©
Start menu, point to Programs, then,
right-click Startup and click Open.
2. Copy FCRead.exe into the Startup window.
The FleetConnect Read text eld displays the
details of recent FCRead actions.
if the Edit Record Validation feature is activated and a DMS
i1000 added new database information during a shift, FCRead
will create an edit transactions le, Edit501.trn. This le will
enact the Edit Record Validation feature in FCEdit.
Edit501.trn
Start>Programs>Startup - Startup Window