Screen 19c: Preset and Delivery (3/7)
Preset and Delivery
The third Preset and Delivery screen is used to set a few
delivery options. Product # and Units will reect values
selected in the previous screens.
Product Type is the current product type associated
with the selected Product # as dened in the Calibration
screens.
Aux1 and Aux2 are used to dene the function of auxiliary
outputs 1 and 2. If there are no external devices attached
to these two outputs, there is no need set these values.
Move the pointer to Aux1 and press ENTER to open a
list box window with the following options:
Monitor Flow Rate: This option causes auxiliary 1 to
activate at the beginning of each delivery. If the ow
rate during the delivery meets or exceeds 40 units
per minute, auxiliary 1 will deactivate. This option is
typically used to monitor the amount of restriction in
a strainer basket or lter. The idea being, when the
lter or strainer is getting clogged, the ow rate will
decrease.
Off: This option deactivates auxiliary 1.
On: This option activates auxiliary 1. It remains activated
even when a delivery is not taking place.
On During Delivery: This option activates auxiliary output
only when the system is in an active delivery. This
also causes header line 11 to print on the ticket.
Move the pointer to Aux2 and press ENTER to open a
list box windows with the following options:
Flow Direction: This option causes auxiliary 2 to indicate
the ow direction through the ow meter.
Off, On, On During Delivery are all dened as in Aux1
above. If set to On During Delivery, header line 12
will print on the ticket.
No-Flow Timer is used to set the no ow timer for the
next delivery. Move the pointer to No-Flow Timer and
press ENTER to open a eld edit window. Enter a value
between “0” and 3600 seconds. This timer will end an
active delivery if there is no ow through the meter in
the set amount of time. If this value is set to “0”, then
each delivery ticket will contain the text “MULTIPLE
DELIVERIES AT ONE SITE. This value is typically set
to 180 (3 minutes).
Press Next (F1) to advance to Screen 19d on page 57.
(3/7) 1
Units: Gallons
Gasoline
On During Delivery
Flow Direction
180
PRESET AND DELIVERY
Product#: 1
Product Type:
Aux1:
Aux2:
No-Flow Timer:
Next Prev Status LCR# Main