Setup Owner manual

51
Save Conguration
Screen 14: Save Conguration
This feature allows the user of LCRHost to save
the calibration and configuration parameters of an
LectroCount in a le. This le can then be used to set up
other LectroCount registers with same data without having
to manually enter data individually.
Press ENTER to open a eld edit window and enter an
alphanumeric Output File name up to 15 characters in
length. When complete, press Save (F1) to save output
le. When Save (F1) is pressed, system will prompt the
operator with the list box window that asks if the current
le should be overwritten with the selected Output File.
Select Yes or No and press ENTER.
The elds saved in the output le are:
DateFormat
Decimals
FlowDirection
MeterID
NoFlowTimer
Odometer
PresetsAllowed
PresetType
Printer
PrintGrossAndParam
PulseOutputEdge
PulsesPerDistance
QtyUnits
Residual
SaleNumber
TempScale
TicketNumber
TicketRequired
TimeUnit
UnitID
VolCorrecteDMS i1000g
For each of the four
product calibrations:
Aux1
Aux2
AuxMult
AuxUnit
BaseTemp
CompensationParam
CompensationType
GrossPreset
GrossTotal
Linearize
NetPreset
NetTotal
PercentTax
PricePerUnit
ProductCode
ProductDescriptor
ProductType
PulsesPerUnit
S1Close
TaxPerUnit
For each of the 10
linearization points:
LinearFlowRate
LinearError
For each of the 12 ticket
header lines:
TicketHeaderLine
Press Main (F5) to return to Screen 2 on page 20. Move
pointer to Load Conguration and press ENTER to
advance display to Screen 18 on page 52.
1SAVE CONFIGURATION
Use the eld below to specify
the output le that will
receive the conguration data
from the LCR.
Output File:
Save LCR# Main