Setup Owner manual

42
Product Calibration
Screen 10e: Product Calibration (5/6)
Aux Multiplier is used to convert quantity delivered to
an alternate volume or inferred mass. In order for this to
be valid, the operator must furnish applicable conversion
factor. For example: To convert from GALLONS of water
to LBS of water, the Aux Multiplier value is 8.345.
Press ENTER to open a eld edit window and enter a
value between 0.000 and 9999.999. If this value is set
to 0”, the AUX MULT value will NOT print on delivery
ticket.
Aux Quantity is not an editable eld. It represents current
quantity of Aux Units for current delivery.
Aux Units is the auxiliary unit of measure that will print
on the delivery ticket. Press ENTER to open a list box
window with the following options:
Gallons
Litres
Cubic M
LBS
KGS
Barrels
Other
Move pointer to desired value and press ENTER. This
selection, as well as Aux Quantity will print on the delivery
ticket.
Gross Totalizer is the amount of non-temperature
compensated product that has passed through the
meter.
Net Totalizer is the amount of temperature compensated
product passed through the meter.
Press Next (F1) to advance to Screen 10f on page 43.
(5/6) 1
Units: Gallons
0.000
0.0
Other
899.3
877.1
PRODUCT CALIBRATION
Product #: 1
Aux Multiplier:
Aux Quantity:
Aux Units:
Gross Totalizer:
Net Totalizer:
Next Prev Cnfg Main