Setup Owner manual

37
Product Calibration
Screen 10a: Product Calibration (1/6)
Product Calibration screens are used to calibrate the
metering system for product(s) which will be measured.
Product # is used to select product number to be
calibrated. The product number will correspond to one of
the product types/calibrations set up in the LectroCount.
At least one product must be calibrated to allow for
deliveries. Press ENTER to open a list box window with
options: 1, 2, 3, or 4.
Product Code will correspond to the Product Number.
The Product Code can also be entered in the Preset
and Delivery menu. Press ENTER to open a eld edit
window. Enter a alphanumeric product code up to ve
characters in length.
Name contains a description of the product that will appear
on the delivery ticket. Press ENTER to open a eld
edit window and enter an alphanumeric name up to 18
characters in length. Ensure product Name is descriptive
of the Product Type and Product Code.
Product Type is used to specify type of product to be
delivered. Press ENTER to open a list box window with
the following eight options:
Ammonia
Aviation
Distillate
Gasoline
Methanol
LPG
Lube Oil
(blank)
Move pointer to desired Product Type and press ENTER
to accept. If (blank) is selected, it indicates there is no
product type associated with the product being calibrated
and delivered.
Press Next (F1) to advance to Screen 10b on page 38.
(1/6) 1
Units: Gallons
Gasoline
PRODUCT CALIBRATION
Product #: X
Product Code:
Name:
Product Type:
Next Cnfg Main