Setup Owner manual

30
Screen 8b: General Setup (2/5)
Sale # is used to track number of transactions LectroCount
processes. This number will increment each time a
delivery is started.
Press ENTER to open a eld edit window to enter starting
number for Sale # and press ENTER to accept. The
LectroCount will use this as the starting value for Sale #
and increment by 1 each time a delivery is started. Once
a Sale # reaches 999999, it will return the count to zero
and resume counting from 1.
Ticket # is similar to Sale # however, Ticket # will
increment each time LectroCount prints a ticket.
If multiple or duplicate tickets are used for transactions,
the ticket number will increment more than the Sale #.
Press ENTER to open a eld edit window and enter
starting number for Ticket # and press ENTER to accept.
LectroCount will use this as the starting value for Ticket #
and increment by 1 each time a delivery ticket is printed.
Once Ticket # reaches 999999, it will return the count to
one and resume counting from 1.
NOTE: If 0 is entered for Ticket #, the Ticket # will not
print on the delivery ticket and it will not increment.
Print Gross & Param? is used to enable or disable
printing of gross volume and compensation parameter
on the delivery ticket if the product is temperature
compensated. In many applications this is required.
Check local Weights & Measures requirements.
Press ENTER to open a list box window. Select No if it is
NOT desired to print the gross volume and compensation
parameter on the ticket. Select Yes if it IS desired to
print the gross volume and compensation parameter on
the ticket.
Volume Corrected Message? is used to enable or disable
printing of the base temperature of net deliveries on the
delivery ticket. In many applications, this is required.
Check local Weights & Measurements requirements.
There are two options for Vol Corrected Msg?. Select
No if the volume corrected message is NOT printed on the
delivery ticket. Select Yes to have the volume corrected
message printed on the delivery ticket. If Yes is selected,
the LectroCount will print a message on the delivery ticket
indicating the delivery volume has been corrected to a
specied base temperature.
If base temperature is in °C, the message will read:
TEMPERATURE VOLUME CORRECTED TO 15 °C
If the base temperature is in °F, the message will read:
TEMPERATURE VOLUME CORRECTED TO 60 °F
NOTE: The base temperature for Linear C and Linear F
can be set to a value other than their default values.
All LectroCount registers feature a calibrated pulse output
which cycles once per least signicant unit of delivery.
The Pulse Out Edge eld allows the LectroCount to
synchronize the calibrated pulse output waveform with the
requirements of an external counter. Depending on the
manufacturer, some counters may increment on the rising
pulse edge of the waveform, some on the falling pulse
edge. Refer to the manufacturer’s manual to determine
the specic requirements.
The List Box Window has two options. Select Rising for
the rising edge of the pulse output. Select Falling for the
falling edge of the pulse output.
Press Next (F1) to advance to Screen 8c on page 31.
General Setup
(2/5) 1
1
1
Yes
Yes
Falling
GENERAL SETUP
Sale #:
Ticket #:
Print Gross & Parameter?
Volume Corrected Message?
Pulse Output Edge:
Next Prev Cnfg Main