Setup Owner manual

29
General Setup
Screen 8a: General Setup (1/5)
General Setup screens are used to set up system
information, deliveries, and ticket printing.
Unit ID is an alpha-numeric identier up to 10 characters
in length used to identify the active LectroCount register.
Press ENTER to open a eld edit window and enter
desired value. Press ENTER to accept.
Presets Allowed denes presets an operator can set
while making deliveries. Preset deliveries allow an
operator the ability to enter a preset volume for delivery.
Upon reaching the preset volume, LectroCount will
typically close a security valve (if equipped) and print a
delivery ticket.
There are four options for Presets Allowed.
BOTH - for both net and gross presets
GROSS - for gross (non-compensated) presets only
NET - for net (temperature compensated) presets
or
NONE - for no presets allowed
Move pointer to desired option and press ENTER to
accept.
NOTE: If the preset feature is used, ensure the S1 CLOSE
eld on page 38 is set for a preset value to work properly.
Date Format is used to determine the format date
displayed and printed. Press ENTER to open a list box
window with the options: DD/MM/YY (Day/Month/Year)
and MM/DD/YY (Month/Day/Year). Select desired format
and press ENTER to select.
Date and Time are elds where current date and time
are entered for the LCR (not for LCRHost). Open the
eld edit window for each and enter current date and
time. Three characters used as a separator are period (.),
forward slash (/), and colon (:). Press ENTER to accept
each value.
Pressing Next (F1) advances display to Screen 8b on
page 30.
Pressing Cnfg (F4) returns display to Screen 7 on page
28.
Pressing Main (F5) returns display to Screen 2 on page
20.
(1/5) 1
Net
MM/DD/YY
01/11/05
11:27:36
GENERAL SETUP
Unit ID:
Presets Allowed:
Date Format:
Date:
Time:
Next Cnfg Main