Operators

16
#4 -Set EZConnect Radio Address
If you are running more than one DMS i1000
FleetConnect in close proximity to another, the
EZConnect button readers will not be able to transmit
data on the same radio address without interference.
The Set EZConnect Radio Address function
can set a unique address where the DMS i1000 unit and
the EZConnect can communicate without interference.
To change the radio address of an EZConnect
device:
1. Turn off all of the EZConnect devices except the one you
want to conî‚¿gure.
2. From the DMS Application List, select FleetConnect.
3. If the Fueler Logon screen does not appear, logoff
the fueler. See page 17.
4. Press F4 (Misc) to open Miscellaneous
Commands list box window.
4. Move the pointer to Setup DMS/EZConnect Link
and press Enter.
5. Select DMS Radio Address and enter a unique 1-4
digit hexadecimal code in DMS Radio Address. See
box to the right.
6. Move the pointer to Set EZConnect Radio
Address and press Enter.
7. Turn on the EZConnect. Wait until the red light stops
blinking.
8. Take a small screwdriver and touch the small metal disc
and the metal around the inside the socket of the button
reader extension at the same time until both EZConnect
lights turn on.
9. While both lights are on, press Enter on the lap pad. A
successful message will appear on the lap pad.
Done (F5) opens Fueler Logon screen
SETUP
If the DMS Radio Address is displayed as
dashes, the DMS i1000 is not responding to
FleetConnect. Select Done (F5) and repeat the
directions from the beginning. If the problem persists,
call the Liquid Controls Service Department.