Safety data sheet

Safety data sheet according to Regulation (EC) No 1907/2006, Annex II
Revision date / version: 21.08.2015 / 0006
Replacing version dated / version: 14.03.2014 / 0005
Valid from: 21.08.2015
PDF print date: 27.08.2015
BIKE Kettenspray 400 ml
Art.: 6055
6.3 Methods and material for containment and cleaning up
If spray or gas escapes, ensure ample fresh air is available.
Active substance:
Soak up with absorbent material (e.g. universal binding agent) and dispose of according to Section 13.
6.4 Reference to other sections
For personal protective equipment see Section 8 and for disposal instructions see Section 13.
SECTION 7: Handling and storage
In addition to information given in this section, relevant information can also be found in section 8 and 6.1.
7.1 Precautions for safe handling
7.1.1 General recommendations
Ensure good ventilation.
Keep away from sources of ignition - Do not smoke.
Take measures against electrostatic charging, if appropriate.
Do not use on hot surfaces.
Eating, drinking, smoking, as well as food-storage, is prohibited in work-room.
Observe directions on label and instructions for use.
Use working methods according to operating instructions.
7.1.2 Notes on general hygiene measures at the workplace
General hygiene measures for the handling of chemicals are applicable.
Wash hands before breaks and at end of work.
Keep away from food, drink and animal feedingstuffs.
Remove contaminated clothing and protective equipment before entering areas in which food is consumed.
7.2 Conditions for safe storage, including any incompatibilities
Keep out of access to unauthorised individuals.
Not to be stored in gangways or stair wells.
Store product closed and only in original packing.
Observe special regulations for aerosols!
Keep protected from direct sunlight and temperatures over 50°C.
Store in a well ventilated place.
Observe special storage conditions (in Germany, e.g., in accordance with the regulations in the "Betriebssicherheitsverordnung").
7.3 Specific end use(s)
No information available at present.
SECTION 8: Exposure controls/personal protection
8.1 Control parameters
Chemical Name
Butane
Content %:
WEL-TWA: 600 ppm (1450 mg/m3) WEL-STEL: 750 ppm (1810 mg/m3) ---
Monitoring procedures: - Compur - KITA-221 SA (549 459)
BMGV: --- Other information: ---
Chemical Name
Propane
Content %:
WEL-TWA: 1000 ppm (ACGIH) WEL-STEL: --- ---
Monitoring procedures: - Compur - KITA-125 SA (549 954)
BMGV: --- Other information: ---
Chemical Name
Isobutane
Content %:
WEL-TWA: 1000 ppm (ACGIH) WEL-STEL: --- ---
Monitoring procedures: - Compur - KITA-113 SB(C) (549 368)
BMGV: --- Other information: ---
WEL-TWA = Workplace Exposure Limit - Long-term exposure limit (8-hour TWA (= time weighted average) reference period) EH40. AGW =
"Arbeitsplatzgrenzwert" (workplace limit value, Germany). | WEL-STEL = Workplace Exposure Limit - Short-term exposure limit (15-minute
reference period). | BMGV = Biological monitoring guidance value EH40. BGW = "Biologischer Grenzwert" (biological limit value, Germany) |
Other information: Sen = Capable of causing occupational asthma. Sk = Can be absorbed through skin. Carc = Capable of causing cancer and/or
heritable genetic damage.
Page 4 of 12