Safety data sheet

Safety data sheet according to Regulation (EC) No 1907/2006, Annex II
Revision date / version: 21.08.2015 / 0017
Replacing version dated / version: 24.04.2015 / 0016
Valid from: 21.08.2015
PDF print date: 24.08.2015
Scheiben-Reiniger-Super-Konzentrat 250 mL
Art.: 1519
Environment - sewage
treatment plant
PNEC 600 mg/l
Environment - oral (animal
feed)
PNEC 53,3 mg/kg feed
8.2 Exposure controls
8.2.1 Appropriate engineering controls
Ensure good ventilation. This can be achieved by local suction or general air extraction.
If this is insufficient to maintain the concentration under the WEL or AGW values, suitable breathing protection should be worn.
Applies only if maximum permissible exposure values are listed here.
8.2.2 Individual protection measures, such as personal protective equipment
General hygiene measures for the handling of chemicals are applicable.
Wash hands before breaks and at end of work.
Keep away from food, drink and animal feedingstuffs.
Remove contaminated clothing and protective equipment before entering areas in which food is consumed.
Eye/face protection:
Tight fitting protective goggles with side protection (EN 166).
If applicable
Face protection (EN 166)
Skin protection - Hand protection:
Chemical resistant protective gloves (EN 374).
Recommended
Safety gloves made of butyl (EN 374)
Minimum layer thickness in mm:
>= 0,5
Permeation time (penetration time) in minutes:
>= 480
The breakthrough times determined in accordance with EN 374 Part 3 were not obtained under practical conditions.
The recommended maximum wearing time is 50% of breakthrough time.
Protective hand cream recommended.
Skin protection - Other:
Protective working garments (e.g. safety shoes EN ISO 20345, long-sleeved protective working garments).
Respiratory protection:
Normally not necessary.
Thermal hazards:
Not applicable
Additional information on hand protection - No tests have been performed.
In the case of mixtures, the selection has been made according to the knowledge available and the information about the contents.
Selection of materials derived from glove manufacturer's indications.
Final selection of glove material must be made taking the breakthrough times, permeation rates and degradation into account.
Selection of a suitable glove depends not only on the material but also on other quality characteristics and varies from manufacturer to
manufacturer.
In the case of mixtures, the resistance of glove materials cannot be predicted and must therefore be tested before use.
The exact breakthrough time of the glove material can be requested from the protective glove manufacturer and must be observed.
8.2.3 Environmental exposure controls
No information available at present.
SECTION 9: Physical and chemical properties
9.1 Information on basic physical and chemical properties
Physical state: Liquid
Colour: Green, Yellow
Odour: Fruity
Odour threshold: Not determined
Page 6 of 14