User's Manual

10
11
Pin Assignments
GND
NC
GND GND
NC
NC
GND
NC
NC
NC
NC
NC
GND
NC
GND
ANTENNA
1
2
3
4
5
6
7
83
7
38
39
40
41
42
43
44
S0
S1
GND GND
PAIR
C1
ACK_OUT
C0
CMD_DATA_OUT
LATCH_EN
S2
S3
LVL_ADJ
RESET
ACK_EN
MODE_IND
9
10
11
12
13
14
15
16 29
30
31
32
33
34
35
36
GND
S7
S6 S5
VCC
POWER_DOWN
GND
S4
RSSI
GND
GND
CMD_DATA_IN
17
18
19
20
21
22
23
24
25
26
27
28
Figure 13: TT Series Transceiver Pin Assignments (Top View)
Pin Descriptions
Pin Number Name I/O Description
1, 3, 6, 11,
17, 22, 23,
28, 34, 39,
42, 44
GND Ground
2, 4, 5, 7, 8,
37, 38, 40, 41
NC
No Electrical Connection. Do not connect
any traces to these lines.
9, 10, 12, 13,
18, 19, 20, 26
S0 - S7 I/O
Status Lines. Each line can be configured
as either an input to register button or
contact closures or as an output to control
application circuitry.
14 LVL_ADJ
1
I
Level Adjust. This line sets the transmitter
output power level. Pull high or leave open
for the highest power; connect to GND
through a resistor to lower the power.
Pin Descriptions Continued
Pin Number Name I/O Description
15 LATCH_EN I
If this line is high, then the status line
outputs are latched (a received command
to activate a status line toggles the output
state). If this line is low, then the output lines
are momentary (active for as long as a valid
signal is received) and which are latched.
16 RESET I
Pull low to perform a soft reset of the
module. This line has an internal pull-up to
POWER_DOWN, may be left unconnected
21 RSSI O
Received Signal Strength Indicator. This line
outputs an analog voltage that increases
with the strength of the received signal. It is
updated once a second.
24 POWER_DOWN I
Power Down. Pulling this line low places the
module into a low-power state. The module
is not functional in this state. Pull high for
normal operation. Do not leave floating.
25 VCC Supply Voltage
27 CMD_DATA_IN I
Command Data In. Input line for the serial
interface commands
29 CMD_DATA_OUT O
Command Data Out. Output line for the
serial interface commands
30, 32 C0 I
This line sets the input/output direction for
status lines S0-S3. When low, the lines are
outputs; when high they are inputs.
31 ACK_OUT O
This line goes high when the module
receives an acknowledgement message
from another module after sending a control
message.
32 C1 I
This line sets the input/output direction for
status lines S4-S7. When low, the lines are
outputs; when high they are inputs.
33 PAIR I
A high on this line initiates the Pair process,
which causes two units to accept each
other’s transmissions. It is also used with
a special sequence to reset the module to
factory default configuration
35 MODE_IND O
This line indicates module activity. It can
source enough current to drive a small
LED, causing it to flash. The duration of the
flashes indicates the module’s current state.
36 ACK_EN I
Pull this line high to enable the module to
send an acknowledgement message after a
valid control message has been received.
43 ANTENNA 50-ohm RF Antenna Port
1. This line has an internal 100kΩ pull-up resistor
Figure 14: TT Series Transceiver Pin Descriptions