User Guide
– –
– –
86 87
SECSTAT - Security Status
Volatile Address = 0xC9
This volatile read-only register provides status of the security features.
The command returns a single byte. Figure 96 shows the meanings of the
bits in the returned value byte.
Figure 95: HumPRO
TM
Series Transceiver Security Status Command and Response
HumPRO
TM
Series Security Status
Read Command Read Response
Header Size Escape Escape Address ACK Address Value
0xFF 0x03 0xFE 0xFE 0x49 0x06 0xC9 V
HumPRO
TM
Series Security Status Value
Bit Status
0 Reserved
1
0 = No volatile key is set
1 = A volatile key is set
2
0 = No non-volatile key is set
1 = A non-volatile key is set
3 Reserved
4 Reserved
5 Reserved
6 Reserved
7 Reserved
Figure 96: HumPRO
TM
Series Security Status Values
JOINST - Join Status
Volatile Address = 0xCA
This volatile read-only register shows the current or previous state of join
activity since the module was last reset.
The command returns a single byte. Figure shows the meanings of the
returned value byte.
Figure 97: HumPRO
TM
Series Transceiver Join Status Command and Response
HumPRO
TM
Series Join Status
Read Command Read Response
Header Size Escape Escape Address ACK Address Value
0xFF 0x03 0xFE 0xFE 0x4A 0x06 0xCA V
HumPRO
TM
Series Join Status Value
Bit Status
0 - 5
Last Join Result (decimal):
Last Operation Successful
0x00: Module unpaired since restart
0x01: New key generated
0x02: Successfully sent address to another unit
0x03: Successfully sent address and key to another unit
0x04: Successfully obtained key from administrator
0x05: Successfully obtained address from administrator
0x06: Successfully obtained key and address from administrator
0x07: New address generated without key
0x08: New key generated without address
Last Operation Failed
0x0A: Fail: operation canceled
0x0B: Fail: timeout
0x0C: Fail: Invalid Generate Key and Address request
0x0D: Fail: Assignment message didn’t contain key
0x0E: Fail: Administrator has no key to send when SECOPT:PSHARE=1
0x0F: Fail: Administrator has no address to send
0x10: Fail: Inconsistent Network Address Registers USRC, UMASK, LASTNETAD
0x11: Fail: LASTNETAD overflow
0x12: Fail: GET_KEY key and address change disabled.
Current Operation
0x20: Detecting PB sequence
0x21: Waiting for joining unit
0x22: Another joining unit detected. Joining is in progress.
6
+0x40: JOINACT – MODE_IND is active with pairing status, serial write
operations are inhibited
Figure 98: HumPRO
TM