Safety Information
Page 52 of 57 Report No.: LCS210301193AS
Attachment No. 1
TRF No. IEC62368_1D
Shenzhen LCS Compliance Testing Laboratory Ltd.
Add: Room 101, 201, Building A and Room 301, Building C, Juji Industrial Park, Yabianxueziwei, Shajing Street, Bao'an District,
Shenzhen, Guangdong, China
Tel: +(86) 0755-8259 1330 | Fax:+(86) 0755-8259 1332 | E-mail:webmaster@lcs-cert.com | http:// www.lcs-cert.com
IEC62368_1D ATTACHMENT
Clause
Requirement + Test
Result - Remark
Verdict
For ITE room applications, automated
information storage systems with combustible
media greater than 0.76 m
3
(27 cu ft) have a
provision for connection of either automatic
sprinklers or a gaseous agent extinguishing
system with an extended discharge.
N/A
Consumer products designed or intended
primarily for children 12 years of age or younger
are subject to additional requirements in
accordance with U.S. & Canadian Regulations.
N/A
Baby monitors additionally comply with ASTM
F2951, Consumer Safety Specification for Baby
Monitors.
N/A
Annex DVA
(5.6.3)
For Pluggable Equipment Type A, the protection
in the installation is assumed to be 20A.
N/A
Annex DVA
(6.3)
The maximum quantity of flammable liquid
stored in equipment complies with NFPA 30.
N/A
Annex DVA
(6.4.8)
For ITE room applications, enclosures with
combustible material measuring greater than
0.9 m
2
(10 sq ft) or a single dimension greater
than 1.8 m (6 ft) have a flame spread rating of
50 or less. For equipment with the same
dimensions for other applications, an external
surface that is not a fire enclosure requires a
min. flammability classification of V-1.
N/A
Annex DVA
(10.3.1)
Equipment with lasers meets the U.S. Code of
Federal Regulations 21 CFR 1040 (and the
Canadian Radiation Emitting Devices Act,
REDR C1370).
N/A
Annex DVA
(10.5.1)
Equipment that produces ionizing radiation
complies with the U.S. Code of Federal
Regulations, 21 CFR 1020 (and the Canadian
Radiation Emitting Devices Act, REDR C1370).
N/A
Annex DVA
(F.3.3.3)
Equipment for use on a.c. mains supply systems
with a neutral and more than one phase
conductor (e.g. 120/240 V, 3-wire) require a
special marking format for electrical ratings.
Additional considerations apply for voltage
ratings that exceed the attachment cap rating or
are lower than the ―Normal Operating Condition‖
in Table 2 of CAN/CSA C22.2 No. 235.‖
N/A
Annex DVA
(F.3.3.5)
Equipment identified for ITE (computer) room
installation is marked with the rated current
N/A
Annex DVA
(G.1)
Vertically-mounted disconnect switches and
circuit breakers have the "on" position indicated
by the handle in the up position
N/A