Safety Information
Page 50 of 57 Report No.: LCS210301193AS
Attachment No. 1
TRF No. IEC62368_1D
Shenzhen LCS Compliance Testing Laboratory Ltd.
Add: Room 101, 201, Building A and Room 301, Building C, Juji Industrial Park, Yabianxueziwei, Shajing Street, Bao'an District,
Shenzhen, Guangdong, China
Tel: +(86) 0755-8259 1330 | Fax:+(86) 0755-8259 1332 | E-mail:webmaster@lcs-cert.com | http:// www.lcs-cert.com
IEC62368_1D ATTACHMENT
Clause
Requirement + Test
Result - Remark
Verdict
ATTACHMENT TO TEST REPORT
IEC 62368-1
U.S.A. AND CANADA NATIONAL DIFFERENCES
(Audio/video, information and communication technology equipment – Part 1: Safety requirements)
Differences according to ................:
CSA/UL 62368-1:2014
TRF template used: ....................... :
IECEE OD-2020-F3, Ed. 1.1
Attachment Form No. .....................:
US_CA_ND_IEC62368_1D
Attachment Originator ....................:
UL(US)
Master Attachment .........................:
Dated 2021-02-04
Copyright © 2021 IEC System for Conformity Testing and Certification of Electrical Equipment
(IECEE), Geneva, Switzerland. All rights reserved.
IEC 62368-1 - US and Canada National Differences
Special National Conditions based on Regulations and Other National Differences
1.1
All equipment is to be designed to allow
installation according to the National Electrical
Code (NEC), ANSI/NFPA 70, the Canadian
Electrical Code (CEC), Part I, CAN/CSA C22.1,
and when applicable, the National Electrical
Safety Code, IEEE C2.
Also, for such equipment marked or otherwise
identified, installation is allowed per the
Standard for the Protection of Information
Technology Equipment, ANSI/NFPA 75.
P
1.4
Additional requirements apply to some forms of
power distribution equipment, including sub-
assemblies.
P
4.1.17
For lengths exceeding 3.05 m, external
interconnecting flexible cord and cable
assemblies are required to be a suitable cable
type (e.g., DP, CL2) specified in the NEC.
N/A
For lengths 3.05 m or less, external
interconnecting flexible cord and cable
assemblies that are not types specified in the
NEC generally are required to have special
construction features and identification
markings.
N/A
4.8
Lithium coin / button cell batteries have modified
special construction and performance
requirements.
N/A
5.6.3
Protective earthing conductors comply with the
minimum conductor sizes in Table G.5, except
N/A