Safety Information

Page 48 of 57 Report No.: LCS210301193AS
IEC 62368-1
Clause
Requirement + Test
Result - Remark
Verdict
TRF No. IEC62368_1D
Shenzhen LCS Compliance Testing Laboratory Ltd.
Add: Room 101, 201, Building A and Room 301, Building C, Juji Industrial Park, Yabianxueziwei, Shajing Street, Bao'an District, Shenzhen,
Guangdong, China
Tel: +(86) 0755-8259 1330 | Fax+(86) 0755-8259 1332 | E-mailwebmaster@lcs-cert.com | http:// www.lcs-cert.com
Battery
identification
Charging at
T
lowest
(C)
Observation
Charging at
T
highest
(C)
Observation
Normal
0
When the battery
temperature reduction to
C, the charge current
from 0.05A to 0.001mA
45C
When the battery temperature
rised to 44.7°C, Unit stop
charging.
Supplementary Information:
Annex
Q.1
TABLE: Circuits intended for interconnection with building wiring (LPS)
P
Note: Measured UOC (V) with all load circuits disconnected:
Output
Circuit
Components
U
oc
(V)
I
sc
(A)
S (VA)
Meas.
Limit
Meas.
Limit
Battery
Normal
4.20
0.42
8
1.57
100
Battery
B-~P- SC
0
0
8
0
100
Supplementary Information:
SC=Short circuit
T.2, T.3,
T.4, T.5
TABLE: Steady force test
P
Part/Location
Material
Thickness
(mm)
Force
(N)
Test Duration
(sec)
Observation
Annex M.4
Table: Additional safeguards for equipment containing secondary lithium
batteries
P
Battery/Cell
No.
Test conditions
Measurements
Observation
U
I (A)
TempC)
Li-ion battery
Normal
4.2
0.050
33.9
No fire or explosion
(other than venting) of
secondary lithium
battery shall occur.
Abnormal
--
--
--
--
Single fault B-~P-
SC
4.2
0.057
34.3
No fire or explosion
(other than venting) of
secondary lithium
battery shall occur.
Supplementary Information: