Safety Information

Page 47 of 57 Report No.: LCS210301193AS
IEC 62368-1
Clause
Requirement + Test
Result - Remark
Verdict
TRF No. IEC62368_1D
Shenzhen LCS Compliance Testing Laboratory Ltd.
Add: Room 101, 201, Building A and Room 301, Building C, Juji Industrial Park, Yabianxueziwei, Shajing Street, Bao'an District, Shenzhen,
Guangdong, China
Tel: +(86) 0755-8259 1330 | Fax+(86) 0755-8259 1332 | E-mailwebmaster@lcs-cert.com | http:// www.lcs-cert.com
Battery
(B-~P- SC)
ED
4.2Vdc
7hrs
--
--
--
--
Max
continuous
discharging
current was
0.053A. The
product
worked as
normal. No
chemicals
leak,
explosion,
molten metal
emission or
expulsion
observed.
Supplementary information:
SC: short circuit; ; OC: over charge; ED: excessive discharge.
Annex
M.3
TABLE: Batteries
P
The tests of Annex M are applicable only when appropriate battery data is not available
P
Is it possible to install the battery in a reverse polarity position? ......................... :
No possible
N/A
Non-rechargeable batteries
Rechargeable batteries
Discharging
Un-
intentional
charging
Charging
Discharging
Reversed charging
Meas.
current
Manuf.
Specs.
Meas.
current
Manuf.
Specs.
Meas.
current
Manuf.
Specs.
Meas.
current
Manuf.
Specs.
Max. current
during normal
condition
--
--
--
50mA
65mA
48mA
65mA
--
--
Max. current
during fault
condition
--
--
--
57mA
(Battery
B-~P-
SC)
65mA
53mA
(Battery
B-~P-
SC)
65mA
--
--
Test results:
Verdict
- Chemical leaks
No hazard
P
- Explosion of the battery
No hazard
P
- Emission of flame or expulsion of molten metal
No hazard
P
- Electric strength tests of equipment after completion of tests
--
N/A
Supplementary information: