Page 46 of 57 Report No.: LCS210301193AS
IEC 62368-1
Clause
Requirement + Test
Result - Remark
Verdict
TRF No. IEC62368_1D
Shenzhen LCS Compliance Testing Laboratory Ltd.
Add: Room 101, 201, Building A and Room 301, Building C, Juji Industrial Park, Yabianxueziwei, Shajing Street, Bao'an District, Shenzhen,
Guangdong, China
Tel: +(86) 0755-8259 1330 | Fax:+(86) 0755-8259 1332 | E-mail:webmaster@lcs-cert.com | http:// www.lcs-cert.com
DC motor
Locked
5.0Vdc
7hrs10mi
ns
--
--
--
--
Unit worked
as normally.
After test, no
damaged, no
hazard. No
significant
temperature
change
Battery
(B-~P- SC)
OC
5.0Vdc
7hrs20mi
ns
--
--
--
--
Max
continuous
charging
current was
0.057A. The
product
worked as
normal. No
chemicals
leak,
explosion,
molten metal
emission or
expulsion
observed.
Battery discharge:
R3
SC
4.2Vdc
10mins
--
--
--
--
BAT
discharging
current:
0.01A.
Unit shut
down,
recoverable.
After test, no
damage, no
hazard.
Battery
SC
4.2Vdc
7hrs15mi
ns
--
--
--
--
Unit cannot
be worked as
normally,
recoverable.
After test, no
damage, no
hazard.