Safety Information

Page 45 of 57 Report No.: LCS210301193AS
IEC 62368-1
Clause
Requirement + Test
Result - Remark
Verdict
TRF No. IEC62368_1D
Shenzhen LCS Compliance Testing Laboratory Ltd.
Add: Room 101, 201, Building A and Room 301, Building C, Juji Industrial Park, Yabianxueziwei, Shajing Street, Bao'an District, Shenzhen,
Guangdong, China
Tel: +(86) 0755-8259 1330 | Fax+(86) 0755-8259 1332 | E-mailwebmaster@lcs-cert.com | http:// www.lcs-cert.com
B.4
TABLE: Fault condition tests
P
Ambient temperature (C) ............................................................. :
24.5-28.0
Power source for EUT: Manufacturer, model/type, output rating . :
--
Component No.
Fault
Condition
Supply
voltage, (V)
Test time
(ms)
Fuse
no.
Fuse
current, (A)
T-
couple
Temp.
(C)
Observation
Empty battery charge and working normally:
C3
SC
5.0Vdc
10mins
--
--
--
--
Input current:
0.01A.
Unit shut
down
immediately,
recoverable.
After test, no
damage, no
hazard.
R2
SC
5.0Vdc
10mins
--
--
--
--
Input current:
0.01A.
Unit shut
down
immediately,
recoverable.
After test, no
damage, no
hazard.