Safety Information

Page 44 of 57 Report No.: LCS210301193AS
IEC 62368-1
Clause
Requirement + Test
Result - Remark
Verdict
TRF No. IEC62368_1D
Shenzhen LCS Compliance Testing Laboratory Ltd.
Add: Room 101, 201, Building A and Room 301, Building C, Juji Industrial Park, Yabianxueziwei, Shajing Street, Bao'an District, Shenzhen,
Guangdong, China
Tel: +(86) 0755-8259 1330 | Fax+(86) 0755-8259 1332 | E-mailwebmaster@lcs-cert.com | http:// www.lcs-cert.com
Circuit Location (x-y)
Operating
Condition
(Normal
/ Describe Single
Fault)
Measured
wattage or
VA
During first
30 s (W / VA)
Measured
wattage or
VA
After 30 s (W
/ VA)
Protective
Circuit,
Regulator, or
PTC Operated?
Yes / No
(Comment)
Resistive
PIS?
Yes/No
--
--
--
--
--
--
Supplementary Information:
A combination of voltmeter, VA and ammeter IA may be used instead of a wattmeter.
If a separate voltmeter and ammeter are used, the product of (VA x IA) is used to determine Resistive PIS
classification.
A Resistive PIS: (a) dissipates more than 15 W, measured after 30 s of normal operation, or (b) under single
fault conditions has either a power exceeding 100 W measured immediately after the introduction of the fault if
electronic circuits, regulators or PTC devices are used, or has an available power exceeding 15 W measured
30 s after introduction of the fault.
8.5.5
TABLE: High Pressure Lamp
N/A
Description
Values
Energy Source Classification
Lamp type .......................................................... :
--
Manufacturer ..................................................... :
--
Cat no. ............................................................... :
--
Pressure (cold) (MPa) ....................................... :
--
MS_
Pressure (operating) (MPa) .............................. :
--
MS_
Operating time (minutes) .................................. :
--
Explosion method ............................................. :
--
Max particle length escaping enclosure (mm) . :
--
MS_
Max particle length beyond 1 m (mm) .............. :
--
MS_
Overall result ..................................................... :
--
Supplementary information:
B.2.5
TABLE: Input test
P
U (V)
I (A)
I rated (A)
P (W)
P rated (W)
Fuse No
I fuse (A)
Condition/status
5.0Vdc
0.05
0.09
0.25
--
--
--
Empty battery charge
4.2Vdc
0.048
--
0.202
--
--
--
Battery discharging
and working normally
Supplementary information:
Equipment may be have rated current or rated power or both. Both should be measured