Safety Information

Page 31 of 57 Report No.: LCS210301193AS
IEC 62368-1
Clause
Requirement + Test
Result - Remark
Verdict
TRF No. IEC62368_1D
Shenzhen LCS Compliance Testing Laboratory Ltd.
Add: Room 101, 201, Building A and Room 301, Building C, Juji Industrial Park, Yabianxueziwei, Shajing Street, Bao'an District, Shenzhen,
Guangdong, China
Tel: +(86) 0755-8259 1330 | Fax+(86) 0755-8259 1332 | E-mailwebmaster@lcs-cert.com | http:// www.lcs-cert.com
- Excessive discharging rate for any battery
P
M.3.3
Compliance ......................................................... :
(See appended Tables and Annex
M.3 and M.4)
P
M.4
Additional safeguards for equipment containing
secondary lithium battery
P
M.4.1
General
P
M.4.2
Charging safeguards
P
M.4.2.1
Charging operating limits
N/A
M.4.2.2a)
Charging voltage, current and temperature ........ :
(See Annex M.4)
M.4.2.2 b)
Single faults in charging circuitry ........................ :
(See Annex B.4)
M.4.3
Fire Enclosure
N/A
M.4.4
Endurance of equipment containing a secondary
lithium battery
P
M.4.4.2
Preparation
P
M.4.4.3
Drop and charge/discharge function tests
P
Drop
P
Charge
P
Discharge
P
M.4.4.4
Charge-discharge cycle test
P
M.4.4.5
Result of charge-discharge cycle test
P
M.5
Risk of burn due to short circuit during carrying
P
M.5.1
Requirement
P
M.5.2
Compliance and Test Method (Test of P.2.3)
P
M.6
Prevention of short circuits and protection from
other effects of electric current
N/A
M.6.1
Short circuits
N/A
M.6.1.1
General requirements
N/A
M.6.1.2
Test method to simulate an internal fault
N/A
M.6.1.3
Compliance (Specify M.6.1.2 or alternative
method) .............................................................. :
N/A
M.6.2
Leakage current (Ma) ......................................... :
N/A
M.7
Risk of explosion from lead acid and NiCd
batteries
N/A
M.7.1
Ventilation preventing explosive gas
concentration
N/A
M.7.2
Compliance and test method
N/A
M.8
Protection against internal ignition from external
spark sources of lead acid batteries
N/A