Instruction Manual
Table Of Contents
- Preface
- Introducing Linksys IP Phones
- Getting Started
- Managing Linksys IP Phones
- Using the 900 Series LCD Display
- Localization
- Changing the Display Background (SPA942/962)
- Using the SPA932 (Sidecar) with the SPA962
- Configuring the Web Service
- RSS Newsfeeds (SPA962)
- Call Appearances and Extensions
- Line Key LEDs
- Using Call Features
- Selecting the Audio I/O Device and Line
- Making Calls
- Answering and Ending Calls
- Hold and Resume
- Call Waiting
- Speed Dialing
- Three-Way Conferencing
- Attended Call Transfer
- Blind Call Transfer
- Call Back
- Message Waiting Indication (MWI)
- Accessing Voicemail
- Muting Calls
- Shared Call Appearances
- Personal Directory
- Caller and Called Name Matching
- Dialing Assistance
- Supplementary Services
- Call Logs
- Audio Volume Adjustment
- Managing Ring Tones
- Configuring a Dial Plan
- System Administration
- Troubleshooting FAQ
- SPA900 Series LCD Command Reference
- Entering Names and Numbers into the Directory
- Entering Directory Names, Numbers and Ring Default
- 2 Speed Dial
- 3 Call History
- 4 Ring Tone
- 5 Preferences
- 6 Call Forward
- 7 Time/Date
- 8 Voice Mail
- 9 Network
- 9.1 DCHP
- 9.2 Current IP Address
- 9.3 Host Name
- 9.4 Domain
- 9.5 Current NetMask
- 9.6 Current Gateway
- 9.7 Enable Web Server
- 9.8 Non DHCP IP Address
- 9.9 Non DHCP Subnet Mask
- 9.10 Non DHCP Default Route
- 9.11 Non DHCP DNS 1
- 9.12 Non DHCP DNS 2
- 9.13 Non DHCP NTP Server 1
- 9.14 Non DHCP NTP Server 2
- 9.15 Multicast Address
- 9.16 Enable VLAN
- 9.17 VLAN ID
- 9.18 CDP
- 10 Product Info
- 11 Status
- 12 Reboot
- 13 Restart
- 14 Factory Reset
- 15 Custom Reset
- 16 Set Password
- 17 Set LCD Contrast
- 18 CallPark Status
- 19 Language (SPA922, 942, and 962)
- 20 GUI Properties (SPA962)
- 21 Web Service (SPA962)
- Linksys IP Phone Field Reference
- Acronyms
- Glossary

5-21
Linksys IP Phone Administrator Guide
Firmware Version 5.1
Chapter 5 Linksys IP Phone Field Reference
Regional Tab
Control Timer Values (sec)
Field Description
Cadence 1 Cadence script for distinctive ring 1.
Defaults to 60(2/4).
Cadence 2 Cadence script for distinctive ring 2.
Defaults to 60(.3/.2, 1/.2,.3/4.
Cadence 3 Cadence script for distinctive ring 3.
Defaults to 60(.8/.4,.8/4).
Cadence 4 Cadence script for distinctive ring 4.
Defaults to 60(.4/.2,.3/.2,.8/4).
Cadence 5 Cadence script for distinctive ring 5.
Defaults to 60(.2/.2,.2/.2,.2/.2,1/4)
Cadence 6 Cadence script for distinctive ring 6.
Defaults to60(.2/.4,.2/.4,.2/4).
Cadence 7 Cadence script for distinctive ring 7.
Defaults to 60(4.5/4).
Cadence 8 Cadence script for distinctive ring 8.
Defaults to 60(0.25/9.75)
Cadence 9 Cadence script for distinctive ring 9.
Defaults to 60(.4/.2,.4/2).
Field Description
Reorder Delay
(Not applicable to SPA901)
Delay after far end hangs up before reorder tone is played. 0 = plays immediately, inf =
never plays. Range: 0–255 seconds.
Defaults to 255.
Call Back Expires Expiration time in seconds of a call back activation. Range: 0–65535 seconds.
Defaults to 1800.
Call Back Retry Intvl Call back retry interval in seconds. Range: 0–255 seconds.
Defaults to 30.
Call Back Delay
(Not applicable to SPA901)
Delay after receiving the first SIP 18x response before declaring the remote end is
ringing. If a busy response is received during this time, the Linksys IP phone still
considers the call as failed and keeps on retrying.
Defaults to 0.5.