Instruction Manual
Table Of Contents
- Preface
- Introducing Linksys IP Phones
- Getting Started
- Managing Linksys IP Phones
- Using the 900 Series LCD Display
- Localization
- Changing the Display Background (SPA942/962)
- Using the SPA932 (Sidecar) with the SPA962
- Configuring the Web Service
- RSS Newsfeeds (SPA962)
- Call Appearances and Extensions
- Line Key LEDs
- Using Call Features
- Selecting the Audio I/O Device and Line
- Making Calls
- Answering and Ending Calls
- Hold and Resume
- Call Waiting
- Speed Dialing
- Three-Way Conferencing
- Attended Call Transfer
- Blind Call Transfer
- Call Back
- Message Waiting Indication (MWI)
- Accessing Voicemail
- Muting Calls
- Shared Call Appearances
- Personal Directory
- Caller and Called Name Matching
- Dialing Assistance
- Supplementary Services
- Call Logs
- Audio Volume Adjustment
- Managing Ring Tones
- Configuring a Dial Plan
- System Administration
- Troubleshooting FAQ
- SPA900 Series LCD Command Reference
- Entering Names and Numbers into the Directory
- Entering Directory Names, Numbers and Ring Default
- 2 Speed Dial
- 3 Call History
- 4 Ring Tone
- 5 Preferences
- 6 Call Forward
- 7 Time/Date
- 8 Voice Mail
- 9 Network
- 9.1 DCHP
- 9.2 Current IP Address
- 9.3 Host Name
- 9.4 Domain
- 9.5 Current NetMask
- 9.6 Current Gateway
- 9.7 Enable Web Server
- 9.8 Non DHCP IP Address
- 9.9 Non DHCP Subnet Mask
- 9.10 Non DHCP Default Route
- 9.11 Non DHCP DNS 1
- 9.12 Non DHCP DNS 2
- 9.13 Non DHCP NTP Server 1
- 9.14 Non DHCP NTP Server 2
- 9.15 Multicast Address
- 9.16 Enable VLAN
- 9.17 VLAN ID
- 9.18 CDP
- 10 Product Info
- 11 Status
- 12 Reboot
- 13 Restart
- 14 Factory Reset
- 15 Custom Reset
- 16 Set Password
- 17 Set LCD Contrast
- 18 CallPark Status
- 19 Language (SPA922, 942, and 962)
- 20 GUI Properties (SPA962)
- 21 Web Service (SPA962)
- Linksys IP Phone Field Reference
- Acronyms
- Glossary

5-13
Linksys IP Phone Administrator Guide
Firmware Version 5.1
Chapter 5 Linksys IP Phone Field Reference
SIP Tab
Response Status Code Handling
RTP Parameters
Field Description
SIT1 RSC SIP response status code for the appropriate Special Information Tone (SIT). For example,
if you set the SIT1 RSC to 404, when the user makes a call and a failure code of 404 is
returned, the SIT1 tone is played. Reorder or Busy Tone is played by default for all
unsuccessful response status code for SIT 1 RSC through SIT 4 RSC.
Defaults to blank.
SIT2 RSC SIP response status code to INVITE on which to play the SIT2 Tone.
Defaults to blank.
SIT3 RSC SIP response status code to INVITE on which to play the SIT3 Tone.
Defaults to blank.
SIT4 RSC SIP response status code to INVITE on which to play the SIT4 Tone.
Defaults to blank.
Try Backup RSC
(not applicable to SPA901)
SIP response code that retries a backup server for the current request.
Defaults to blank.
Retry Reg RSC
(not applicable to SPA901)
Interval to wait before the Linksys IP phone retries registration after failing during the last
registration.
Defaults to blank.
Field Description
RTP Port Min Minimum port number for RTP transmission and reception. <RTP Port Min> and <RTP
Port Max> should define a range that contains at least 4 even number ports, such as 100 – 106.
Defaults to 16384.
RTP Port Max Maximum port number for RTP transmission and reception.
Defaults to 16482.
RTP Packet SizeSPA901
(not applicable to SPA901)
Packet size in seconds, which can range from 0.01 to 0.16. Valid values must be a multiple
of 0.01 seconds.
Defaults to 0.030.
Max RTP ICMP Err
(not applicable to SPA901)
Number of successive ICMP errors allowed when transmitting RTP packets to the peer
before the Linksys IP phone terminates the call. If value is set to 0, the Linksys IP phone
ignores the limit on ICMP errors.
Defaults to 0.