Specifications

Table Of Contents
BOOT MODE FUNCTIONS
1999 LinkPoint® International, Inc. 18 L3FRET1 Reference Manual
Model Number
Follow the procedures outlined below to find out the terminal model (version) of the ROM and
RAM.
Display Message Operator Action
_____READY XXX Hold down the [ALPHA] key and press [7] [1] [3] [9]. Release
JAN-03-00_MON_12:00P the [ALPHA] key to enter the boot mode.
[] [] []
__CLEAR_to_resume Press the right [] key to select SETUP.
_ Time__Load__Setup
[] [] []
Setup Press the middle [] key to select MODEL.
Ports Model Test
[] [] []
Model 256k Press the left [] key to select ROM.
ROM <ver> RAM
[] [] []
ROM Version V01.00x Terminal displays ROM version. Press [CLEAR].
[] [] []
Model 256k Press the right [] key to select RAM.
ROM <ver> RAM
[] [] []
RAM Version: XXXX Terminal displays the application (in RAM) version. Press
[CLEAR] four times to reboot the terminal.
[] [] []