Data Sheet
Linkplay Technology Inc. A128 SOM Datasheet Rev.03
Confidential of Linkplay Technology Inc. 13
Figure 3-1 A128 Length and Width
Figure 3-2 A128 Pin Header Dimension
6 Environmental Characteristics
6.1 Environmental Ratings
The environmental ratings are shown as following table.
Characteristic Value Units Conditions/Comments
Ambient Operating Temperature Range -5 ~ 40 ℃
Operating Temperature Range -5 ~ 70 ℃
Storage Temperature Range Without Operation -5 ~ 45 ℃
Relative humidity
Less than 80 % Operating
Less than 60 % Storage
6.2 Electrostatic Discharge Specifications
Extreme caution must be exercised to prevent electrostatic discharge (ESD) damage. Proper use of wrist and heel grounding
straps to discharge static electricity is required when handling these devices. Always store unused material in its antistatic
packaging.
ESD Specifications
Type Symbol Condition ESD Rating Unit
ESD Handling ESD_HAND_HBM
Human Body Model Contact Discharge
per
JEDEC EID/JESD22-A114
1000 V
Machine Model ESD_HAND_MM Machine Model Contact 30 V