User guide
August 30, 2002 Manual Version 1.0
3.10
Figure 3.7 Main Die Protection Screen in Run Mode for Module 1, Channels 1-8
Figure 3.8 Channel Settings Screen for Module 1, Channel 5
Once Program Mode is entered, the upper right softkey on screens throughout the OmniLink II
Press Automation Control is used in the editing (change) process of any setting selected by use of
the arrow keys on the operator terminal. See Sections 3.7 and 3.8.
In Key Only Access Mode,
the Channel Settings Softkey
will select the DP Channel
Settings screen so settings
can be viewed
in Run Mode,
but the Program/Run switch
must be turned to Program
to chan ge
settings on the
DP Channel Settings screen.
Stroke
Mode
Drive
Speed
Stroke
Speed
SPM
SPM
0
0
Order
Counter
SYSTEM STATUS
Counter OFF
Die
Protection
CHANNEL
SETTINGS
CHANNEL
DIAGS
NEXT
PAGE
0
0
OK
TO P
EXIT
Ch Channel Type Description Status State
1 S tatic Stock Buckle OK Off
2 Not Used OK Off
3 1 Part Detector Edge Part Out OK Off
4 In Position Die Cam Retracted OK On
5 Cyclic Str ipp er Le ft Front OK Of f
6 Cyclic Str ipper Right Fron t OK Of f
7 Cyclic Str ipp er Le ft Rear OK Of f
8 Cyclic Stripper Right Rear OK Off
Module 1 - Channel 5 Details
Input Type:
Stop Type:
Bypassed:
Delay Time:
Delay Strokes:
Window On :
Window Of f:
Normally OFF
Top Stop
No
0 msecs
0 S trokes
154
0
213
0
0
90270
180
Channel
Status
OK
System Status: OK
Module Status: OK
SoftKeys
5
RESET
FAULT
Appears only with
Program/Run switch
in Program Position.
Stroke
Mode
Dr iv e
S pee d
Stroke
S pee d
SPM
SPM
0
0
Order
Counter
SYSTEM STATUS
Coun ter OFF
DP Chan
Settings
CHANGE
SETTI NG
CHA NNEL
DIAGS
NEXT
CHANNEL
0
0
OK
TOP
EXIT
0
90270
180
Di e Prot. Channel Settings Modul e: 1 Channel: 5
Channel Type:
Descripti on:
Input Type:
Stop Ty p e:
Bypassed:
Delay Time:
Delay Stro kes :
Wi ndow O n:
Wi nd ow O ff:
C ycl ic
Left Front Stripper
Normal ly OFF
Top Stop
No
0 mse cs
0 Stro kes
154
0
213
0
Help
Sets the type of Logic
to apply to the
channel
Cyclic - Norm. OFF
Used to monitor events that occur
once per machine cycle. The input
must be O N so mewhere in the timi ng
windo w AND O FF somewhere in the
timing window.
PRE VIOUS
CHA NNEL
DECREMENT
ON AN GLE
IN CREM ENT
ON AN GLE
DE CREMENT
OFF ANGLE
IN CREM ENT
OFF ANGLE
SoftKeys
CHANGE SETTING,
CHANGE NAME, or
CHANGE NUMBER
in Program Mode
depending on setting
selected.