User guide

August 30, 2002 Manual Version 1.0
3.6
Figure 3.3 The Die Protection Channel Settings Screen in Program Mode
When the Channel Type setting is selected, the upper right softkey legend is CHANGE SETTING.
Pressing the CHANGE SETTING softkey will cause a list box to appear as on the screen as shown
in Figure 3.4, and the upper right softkey legend will change to SELECT. The arrow keys are used
to highlight the desired item on the list after which the SELECT softkey is pressed to enter the
selected item and remove the list box.
Figure 3.4 List Box for Die Protection Type and SELECT Softkey
2. A CHANGE NAME softkey will appear on the screen when a description or name setting is
selected. In some cases, a screen showing a list of default names or descriptions commonly used for
the setting will appear when this softkey is pressed, allowing selection of a name or description to
enter by pressing a SELECT softkey that appears for this type of setting. In addition, you may edit
(change) existing or unnamed items on the list by selecting the item and pressing an EDIT NAME
softkey on the screen after your selection. In this case, another popup menu, the Text Entry menu,
will appear that allows you to enter letters, numbers, and spaces for the name or description selected.
This also can be illustrated by use of the Die Protection Channel Settings screen. If the setting for
Description is selected, the upper right softkey legend will be CHANGE NAME. Pressing this key
causes the Die Protection Names screen to appear as shown in figure 3.5
Stroke
Mode
Dr iv e
S pee d
Stroke
S pee d
SPM
SPM
0
0
Order
Counter
SYSTEM STATUS
Coun ter OFF
DP Chan
Settings
CHANGE
SETTI NG
CHA NNEL
DIAGS
NEXT
CHANNEL
0
0
OK
TOP
EXIT
0
90270
180
Di e Prot. Channel Settings Modul e: 1 Channel: 5
Channel Type:
Descripti on:
Input Type:
Stop Ty p e:
Bypassed:
Delay Time:
Delay Stro kes :
Wi ndow O n:
Wi nd ow O ff:
C ycl ic
Left Front Stripper
Normal ly OFF
Top Stop
No
0 mse cs
0 Stro kes
154
0
213
0
Help
Sets the type of Logic
to apply to the
channel
Cyclic - Norm. OFF
Used to monitor events that occur
once per machine cycle. The input
must be O N so mewhere in the timi ng
windo w AND O FF somewhere in the
timing window.
PRE VIOUS
CHA NNEL
DECREMENT
ON AN GLE
IN CREM ENT
ON AN GLE
DE CREMENT
OFF ANGLE
IN CREM ENT
OFF ANGLE
SoftKeys
CHANGE SETTING,
CHANGE NAME, or
CHANGE NUMBER
in Program Mode
depending on setting
selected.
Not Used
Static
Cyclic
Transfer
In Position
1 Part Detector Edge
1 Part Detector Pass
2 Part Detector Edge
2 Part Detector Pass
Custom
SELECT
Legend for upper right softkey