User guide

August 30, 2002 Manual Version 1.0
2.5
Figure 2.5 Dimensions for Mounting OmniLink II LCD Operator Terminal
Section 2.2.2 Mounting the Resolver
Mounting the resolver to be driven in a one to one ratio by the crank or eccentric shaft. The resolver
may be direct driven by a coupling off the center of the shaft or driven by a chain and sprockets as
shown in Figure 2.6.
Figure 2.6 Mounting the 2500 or 5000 Resolver
Strok e
Mode
Drive
Spee d
Strok e
Spee d
SP M
SP M
0
0
Or d er
Counter
SYS TEM STATUS
Co un te r OFF
MAIN
SCREEN
PRE SS
CONTROL
AUTO
SETS
TONNAGE
MON ITOR
DIE
PROTECTION
LIM IT
SWITCH
JOB
SETUPS
0
0
MOTOR
SPE ED
STATUS:
OK
STATUS:
ALL C ON DI TI ONS OKAY
STATUS:
ALL CON DI TI ONS OKAY
STATUS:
ALL CON DITI ONS OKAY
JOB NUMBER DE SCRIP TION
100000 FRONT BR AC KET
COUN TER L IMI T QUANTI TY STATE
ORDER
BAT C H
SPM
0
% LOAD
161
2000
500
7
7
ON
ON
READY TO STROKE
TOP
COUNTERS
CH G
AC C
CLR
ENT
123
456
789
0
BRAKE
MO NI TOR
ON
OmniLink II LCD
OPERATOR TERMINAL
LIN K ELECTRIC & SAFETY C ONTROL CO.
444 McN ALLY DR. NASHVILLE, TN 37211
PHONE (615) 833-4168
OK
PROG RUN
11.125
(28.26)
11.00 ( 27.74)
OmniLink II Press Automation Control
13.50 (34.29)
11.65
(29.59)
10.4
(26.42)
0.312 (.792)
Diameter
(4 Places)
Enclosure Depth: 6 (15.24)
PRESS
CROWN
RESOLVER
CRANK OR
ECCENTRIC
SHAFT
CHAIN
NOTE! A CHAIN GUARD
IS NECESSARY TO MEET
OSHA 1910.219 STANDARDS