Setups Module
October 16, 2008 Manual Version 1.1
6-5
Sys not Detected
The hardware necessary for the system cannot be detected. For
example if it was attempted to turn on a slide adjust system SS1 and a
slide adjust system card was not installed in slot SS1, this error would
appear. This could be either defective hardware or missing hardware.
Section 6.5 Slide Adjust “Status” Messages
In Position The slide is within tolerance of the slide setpoint.
Up Lim Switch The slide has hit the mechanical up limit switch and can go no higher.
Down Lim Switch The slide has hit the mechanical down limit switch and can go no
lower.
Upper Limit The slide has gone as high as the max position programmed in the
configurations menu and will not be allowed to go higher.
Lower Limit The slide has gone as low as the min position programmed in the
configuration menu and will not be allowed to go lower.
Moving Up The slide is moving up.
Moving Down The slide is moving down.
System Off The slide adjust system is turned off. The slide can still be manually
moved by using the jog up and jog down buttons. The slide position
will still be shown if the position transducer is still functioning
correctly.
AM-Waiting for CBAL (Auto-Move Waiting for Counterbalance) - The automatic move
function of the slide adjust system is waiting for the counterbalance to
come to its correct pressure before automatically moving the slide.
AM-Waiting Top
(Auto-Move Waiting for Top) The automatic move function of the
slide adjust system must be at the top of the stroke for automatic
positioning to occur. If a job is recalled at the bottom of the stroke, this
message will be displayed until the press is at the top.
AM-Waiting SA Sw (Auto-Move Waiting for Slide Adjust Switch) The automatic move
function of the slide adjust system is waiting for the slide adjust switch
to be turned on. The slide cannot move while the slide adjust switch is
in the off position.
Slide High The slide is higher than the slide setpoint plus tolerance.
Slide Low The slide is lower than the slide setpoint minus tolerance.