Instruction Manual
MicroLink: Operator Interface Terminal
Manual Revision 1.0 4/20/99 B-1
APPENDIX B. ELECTRICAL SPECIFICATIONS
B.1 MicroLink / MultiSet Enclosure
Size: 11.2" wide, 7.2" high, 4" deep
Operating Temperature: 45°C (113°F) Maximum Ambient
B.2 801-1 MicroLink Logic Board
Input Power Supply: Voltage: 115VAC ± 15VAC, 60 Hz, Single Phase
Fuse: 250 mA, Slow Blow, (5mm x 20mm)
Electromechanical Relay: Voltage: 120VAC, 60 Hz
(or) 30VDC
Current: 5Amp Continuous (AC or DC)
B.3 801-3 Air System Control Board
Electromechanical Relay: Voltage: 120VAC, 60 Hz
(or) 30VDC
Current: 5Amp Continuous (AC or DC)
Normally Open, Energized Closed
AC Solid State Relays: Voltage: 120VAC, 60 Hz
Current: 1Amp Continuous
20 Amp 16ms
5 Amp 75ms
Fuse: 2 Amp Fast-Blow Picofuse
B.4 801-4 Rotary Shut Height Control Board
AC Solid State Relays: Voltage: 120VAC, 60 Hz
Current: 1Amp Continuous
20 Amp 16ms
5 Amp 75ms
Fuse: 2 Amp Fast-Blow Picofuse
B.5 801-5 Linear Shut Height Control Board
AC Solid State Relays: Voltage: 120VAC, 60 Hz
Current: 1Amp Continuous
20 Amp 16ms
5 Amp 75ms
Fuse: 2 Amp Fast-Blow Picofuse