User Manual

STOV-002 to AMS-1000 boost controller:
The Stage input for the AMS-1000 can be congured for either ground or +12v. It can be pulsed input
or an analog voltage input.
To connect the STOV-002 to the AMS-1000 we recommend using analog voltage input setting and the
analog voltage output from our MPH switch (Yellow voltage out wire).
The voltage out data from the STOV-002 is not modied by any of the switch settings. The pulse per
mile signal into the STOV-002 from your ECM or other device needs to be calibrated correctly. If
this data is correct, then the voltage output from the STOV-002 will also be correct. Analog volt-
age output is 0-5 volt analog output proportional to speed. Speed range is 0 – 250 MPH (0 volts = 0
MPH, 5 volts = 250 MPH). Analog output will increase at a rate of .02 volt per MPH (linear rela-
tionship between speed and voltage). The analog voltage output function operates the same in all
modes.
If your input signal into the STOV-002 is not calibrated correctly you can scale the STOV-002 signal to
make the readings still work in the AMS-1000. You can easily check to see if the STOV-002 signal
is calibrated correctly using a volt meter on the yellow signal output wire.
In order to cover a wide voltage range in analog mode all 6 stages need to be turned on. Even if the
user sets 5 of the same boost level. Each stage has a +/-V adjustable setting. The AMS-1000 can be
programmed to not activate until 1.5 volts for the rst stage if desired. If the vehicle will never see
255mph then the maximum speed can be used to determine the working voltage range. The range/
gap is adjustable for each stage.
For example
· Stage 1 = Target Voltage = .5 v, range +/-.4v
· Stage 2 = Target voltage = 1.3v, range +/-.4v
· Stage 3 = Target voltage = 2.1v, range +/-.4v
· Stage 4 = Target voltage = 2.9v, range +/-.4v
· Stage 5 = Target voltage = 3.7v, range +/-.4v
So in the example ranges provided above the stage entry speeds would be 5 mph, 45 mph, 85 mph, 125
mph, 165 mph and 205 mph (see table below).
Input Values Calculated Values
Target Range Min Max MPH
Stage
1 0.5 0.4 0.1 0.9 25 5 45
2 1.3 0.4 0.9 1.7 65 45 85
3 2.1 0.4 1.7 2.5 105 85 125
4 2.9 0.4 2.5 3.3 145 125 165
5 3.7 0.4 3.3 4.1 185 165 205
6 4.5 0.4 4.1 4.9 225 205 245
If the voltage does not fall within a programmed range for a stage the activation turns off.
Page 7 of 12