User Manual

Page
3.
5. After test tting the rubber hose (PN:
5283K31) from the bladder to where it will
connect to the differential, cut the hose to
length.
6. Using the two (2) 13.3mm Oetiker clamps
(PN:52545K51) and the correct length of hose,
connect the hose to the hose joiner and the
differential.
3. Select a location for the bladder on the
vehicle that will allow the uid to be gravity-fed
back into the differential or transmission. Mount
the bladder (PN: XX04556-0010) to the vehicle
where desired.
4. Press the 1/4” to 1/2” hose joiner (PN:
WWG4HFL2) into the bladder tube selected
in the previous step. Secure the hose joiner
to the bladder using a 17.0mm Oetiker clamp
(PN:52545K55). Tighten the clamp with a pair
of Oeticker clamp pliers (or equivalent).