13. If a manual overide switch is not being 
installed, install the plug seal into the end 
of the supplied connector, and close the 
retainer clip on the connector.Then install the 
connector on to the single connector that is on 
the harness. 
If you are installing a manual overide switch, 
skip to step 14.
14. If installing a manual override switch, crimp 
the female terminal onto 16 gauge wire and 
make sure the seal is crimped under the large 
tangs on the terminal. Then push to seat 
the terminal into the connector and close the 
retaining clip. Run the wire to a switch rated 
for at least 15 amps, and connect that switch 
to either an always hot, or accessory power 
source that uses a 15 amp fuse. 
If not installing a manual overide switch, skip 
to step 15.
15. Install the new VariMax intercooler pump 
harness onto the factory intercooler pump 
mounting bracket by inserting the end of the 
wire loom retaining clip back into the bottom 
hole of the mounting bracket. Make sure to 
push the retaining clip through the hole as 
far as you can to ensure that the harness is 
securely fastened to the vehicle.
16. Plug the 2-way harness connector into the 
new VariMax intercooler pump harness.