Owner's Manual

NOTE: Check the marking on the operator outer carton and the
wiring diagram on the inside control box cover for the wiring
type.
B WIRING
To Open - Momentary Contact
To Close - Momentary Contact
To Stop- Momentary Contact
B1 WIRING
To Open - Momentary Contact
To Close - Momentary Contact
To Stop- Momentary Contact
Door Edge/Photoelectric Input will stop the door when closing.
B2 WIRING
To Open - Momentary Contact
To Close - Momentary Contact
To Stop- Momentary Contact
Open Override- Standard
Door Edge/Photoelectric Input will reverse a closing door to
full open - door can be stopped with the STOP button at all times.
Single Button Radio Control Input will open or close door and
reverse to open if closing but will not stop the door.
C WIRING
To Open - Momentary Contact
To Close - Constant Pressure:
Door will stop if pressure is released from CLOSE button
To Stop- Momentary Contact
C1 WIRING
To Open - Momentary Contact
To Close - Constant Pressure:
Door will stop if pressure is released from CLOSE button
To Stop- Momentary Contact
Door Edge/Photoelectric Input will stop the door when closing.
D WIRING - 2 Button Control
To Open - Momentary Contact
To Close - Constant Pressure
To Stop- Door will stop if pressure is released or when the
opener activates a limit switch at full open or full closed.
WIRING TYPES
E WIRING - 2 Button Control
To Open - Momentary Contact
To Close - Constant Pressure:
If pressure is released door will reverse to full open
To Stop- Door will stop when the opener activates a limit switch
at full open or full closed. Door cannot be stopped in mid
travel.
E2 WIRING -2 Button Control
To Open - Momentary Contact
To Close - Constant Pressure:
If pressure is released door will reverse to full open
To Stop- Door will stop when the opener activates a limit switch
at full open or full closed. Door cannot be stopped in mid
travel.
Door Edge/Photoelectric Input will reverse a closing door to
full open and door cannot be stopped.
T1 WIRING
To Open - Momentary Contact
To Close - Momentary Contact
To Stop- Momentary Contact
Open Override- Standard
Door Edge/Photoelectric Input will reverse a closing door to
full open - door can be stopped with the STOP button at all
times..
Optional Adjustable Timer closes the door automatically. Time
interval resets when open button, open override, door edge or
auxiliary control is activated.
Optional Defeat Switch locks out timer when not required.
T2 WIRING
To Open - Momentary Contact
To Close - Momentary Contact
To Stop- Momentary Contact
Door Edge/Photoelectric Input will reverse a closing door to
full open - door can be stopped with the STOP button at all
times..
Optional Adjustable Timer closes the door automatically. Time
interval resets when door edge or auxiliary control is activated.
OPEN button will not start or reset timer.
Optional Defeat Switch locks out timer when not required.
OPERATION & ADJUSTMENT INSTRUCTIONS
14